期刊文献+

CFP柄假体行全髋关节置换术的中期疗效

The medium-term efficacy of total hip replacement with CFP handle prosthesis
原文传递
导出
摘要 目的探讨CFP柄假体行全髋关节置换术的中期疗效。方法选取CFP柄假体行全髋关节置换术患者32例(34髋),术前诊断:股骨颈骨折6例,股骨头坏死12例,骨性关节炎10例,强直性脊柱炎3例,色素沉着绒毛结节性滑膜炎1例。分别于术后10d、1个月、6个月、1年(以后每年)对髋关节功能和X线片表现进行随访。结果32例手术患者无一例手术感染或神经血管损伤等并发症,术后x线片提示股骨柄假体位置良好。髋关节功能从术前Harris评分平均32.6(20~53)分,恢复至术后平均95.3(90—100)分,无一髋需行翻修手术。术后半年Engh评分均在10分以上。结论CFP柄假体行全髋关节置换术中期疗效良好,可作为初次全髋置换术的选择之一。 Objective To investigate the medium-term efficacy of total hip replacement with CFP handle prosthesis. Methods Thirty-two patients (34 hips) undergoing total hip replacement with CFP handle prosthesis were selected. The preoperative diagnosis was: femoral neck fracture in 6 cases, femoral head necrosis in 12 cases, osteoarthritis in 10 cases, ankylosing spondylitis in 3 eases, and pigmentation villi nodular synovitis in 1 case. Ten days, 1 month, 6 months, and 1 year (a year later) after surgery, the hip joint function and X ray film performance were followed up. Results There was no complication such as infect and injury of blood vessel and nerve. Postoperative X ray film showed the femoral handle prosthesis position was good. The average Harris hip score was 32.6 (20 - 53) scores before surgery, and back to 95.3(90 - 100) scores after surgery, no patients needed revision surgery. Postoperative Engh score was above 10 scores after half a year. Conclusion The medium-term efficacy of total hip replacement with CFP handle prosthesis is good, and can be used as one of the choice of primary total hip replacement.
出处 《中国医师进修杂志》 2015年第12期917-919,共3页 Chinese Journal of Postgraduates of Medicine
关键词 关节成形术 置换 股骨颈 治疗结果 Arthroplasty, replacement, hip Femur femoral Treatment outcome
作者简介 通信作者:杨沛彦,Email:ypy211@163.com
  • 相关文献

参考文献9

  • 1Gruen TA,McNeice GM,Amstutz HC. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening[J ]. Clin Oahop Relat Res, 1979( 141 ): 17-27.
  • 2Engh CA,Massin P,Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components [J]. Clin Orthop Relat Res, 1990(257 ) : 107-128.
  • 3Harris WH. Traumatic arthritis of the hip after dislocation and aeetabular fractures : treatment by mold arthroplasty. An end-resuh study using a new method of result evaluation [ J ]. J Bone Joint Surg Am, 1969,51(4):737-755.
  • 4Brooker AF, Bowerman JW, Robinson RA, et al. Ectopic ossification following total hip replacement. Incidence and a method of classification[J]. J Bone Joint Surg Am, 1973,55(8) : 1629-1632.
  • 5Amenabar T, Marimuthu K, Hawdon G,et al. Total hip arthroplasty using a short-stem prosthesis:restoration of hip anatomy [J]. J Orthop Surg (Hong Kong), 2015,23 ( 1 ) : 90-94.
  • 6Nam D, Nunley RM, Sauber TJ, et al. Incidence and location of pain in young, active patients following hip arthroplasty [J]. J Arthroplasty, 2015,23 ( 15 ) : 423-424.
  • 7Huiskes R,Weinans H,van Rietbergen B. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials[J], Clin Orthop Relat Res, 1992(274) : 124-134.
  • 8Namba RS, Keyak JH, Kim AS,et al. Cementless implant composition and femoral stress. A finite element analysis [J]. Clin Orthop Relat Res, 1998( 347 ) : 261-267.
  • 9Dodge BM,Fitzrandolph R,Collins DN. Noncemented porous coated anatomic total hip arthroplasty [ J ]. Clin Orthop Relat Res, 1991(269) : 16-24.