摘要 人工髋关节试验机是研究人工髋关节磨损的重要工具。考虑髋关节的运动学、动力学状态,设计了一种新型的人工髋关节试验机,能够模拟正常步行、慢跑等运动,以及关节润滑状态。与其他的髋关节试验机相比,该试验机增加了冲击模块,可研究冲击力对人工髋关节磨损的影响。采用ANSYS Workbench对试验机进行了静态分析和模态分析,结果表明试验机满足强度和刚度要求,并且在试验过程中不会发生共振,能够为人工髋关节的磨损研究提供可靠的试验数据。 The artificial hip simulator is an important test rig used in evaluating the wear of artificial hip joint. A novel artificial hip simulator is designed according to the kinematics and kinetics of the hip joint,which can simulate normal walking and jogging as well as joint lubrication. Compared with other hip simulators,an impact module is designed to study the effect of impact force on the wear of artificial hip joint. Static analysis and modal analysis are carried out by ANSYS Workbench. The results show that the hip simulator meets the requirement of stiffness and strength,and resonance does not occur during the experiment. It is indicated that the artificial hip simulator can provide reliable experimental data for the wear analysis of artificial hip joint.
出处 《机械设计》 CSCD 北大核心 2015年第10期24-27,共4页 Journal of Machine Design
基金 国家自然科学基金资助项目(51175406)
关键词 人工髋关节试验机 冲击力 ANSYS WORKBENCH 静态分析 模态分析 artificial hip simulator impact force ANSYS Workbench static analysis modal analysis
作者简介 刘书杰(1988-),男,硕士研究生,研究方向:结构设计、生物摩擦学。E-mail:wuxjekeji23456@126.com
  • 相关文献

参考文献13

  • 1Charnley J. Arthroplasty of the hip: a new operation[J]. The Lancet, 1961,277 : 1129-1132.
  • 2Bowsher J G, Shehon J C. A hip simulator study of the influ- ence of patient activity level on the wear of crosslinked polyethylene under smooth and roughened femoral conditions [J]. Wear, 2001,250( 1 ) : 167-179.
  • 3Barbour P S M,Stone M H,Fisher J. A hip joint simulator study using simplified loading and cycles generating physio- logical wear paths and rates [J]. Journal of Engineering in Medicine, 1999,213(6) :455-467.
  • 4Scholes S C, Unsworth A. Pin-on-plate studies on the effect of rotation on the wear of metal-on-metal samples[J]. Jour-nal of Materials Science:Materials in Medicine,2001,12 (4) :299-303.
  • 5Johnston R C,Smidt G L. Measurement of hip-joint motion during walking-evaluation of an electrogoniometric method [J3. The Journal of Bone & Joint Surgery,1969,51 (6): 1083-1094.
  • 6Bergmann G,Deuretzbacher G,Heller M,et al. Hip contact forces and gait patterns from routine activities[J]. Journal of Biomechanics, 2001,34 (7) : 859-871.
  • 7Calonius O,Saikko V. Slide track analysis of eight contem- porary hip simulator designs [J ]. Journal of Biomechanics, 2002,35 ( 11 ) : 1439-1450.
  • 8Brockett C,Williams S,Jin Z,et al. Friction of total hip re- placements with different bearings and loading conditions [J]. Journal of Biomedical Materials Research Part B:Ap- plied Biomaterials, 2007,81 (2) : 508-515.
  • 9Qin Liguo,Lin Ping,Zhang Yali,et al. Influence of surface wettability on the tribological properties of laser textured CoCrMo alloy in aqueous bovine serum albumin solution[J]. Applied Surface Science, 2013,268 : 79-86.
  • 10Scholes S C, Green S M,Unsworth A. The wear of metal-on- metal total hip prostheses measured in a hip simulator[J]. Journal of Engineering in Medicine, 2001,215 (6) : 523-530.