期刊文献+

NaI探测器搜寻γ源定位准直器模拟设计 被引量:5

The Simulation Design of a Positioning Collimator to Locate the Gamma Radiation Source with NaI Detector
在线阅读 下载PDF
导出
摘要 为尽快搜寻丢失的γ放射源,模拟设计了用NaI探测器确定γ源方位的铅准直定位装置。设计针对铅准直NaI探测器,运用MCNP软件模拟定位γ源。模拟结果表明,设计的铅准直NaI探测器能够识别γ射线的方向,且角度分辨率高,放射源模拟定位的偏差小,在多个放射源形成的辐射场中能对各个放射源进行定位。 In order to find the missing gamma radioactive source as soon as possible, a NaI detector which is used as the lead collimator positioning device is simulated and designed to locate the gamma radiation source. In this study, MCNP software was used to simulate the lead collimation of NaI detector to determine the position of gamma radiation source. The analog results showed that the designed lead collimation of NaI detector can identi- fy the direction of gamma radiation with a high angular resolution and a low positioning deviation in simulation. In addition, the lead collimation NaI detector can get the positioning of each radiation source in a radiation field produced by a plurality of radiation sources.
出处 《核电子学与探测技术》 CAS 北大核心 2015年第4期354-360,共7页 Nuclear Electronics & Detection Technology
关键词 准直探测器 放射源定位 准直管 屏蔽体 MCNP collimated detector radiation source location collimator shield MCNP
作者简介 谭军文(1991-),男,湖南衡阳人,硕士研究生,主要从事放射源定位方法研究。通信作者:左国平,南华大学核科学技术学院副教授.主要研究方向:反应堆热工、核技术。电子信箱:zuogp@yahoo.com.cn
  • 相关文献

参考文献4

二级参考文献7

  • 1黄超云,王晓涛,王晓峰,刘怡刚,周启甫.γ探伤辐射事故类型与预防[J].中国辐射卫生,2007,16(2):208-209. 被引量:6
  • 2[1]IAEA. IAEA methods to identify and locate spent radiation sources. IAEA-TECDOC-804,1995.
  • 3IAEA. Code of Conduct on the Safety and Security of Radioactive Sources. 2004: 3.
  • 4IAEA. The Radiological Accident in Goiania. 1988:4-1.
  • 5IAEA. The Radiological Accident in Samut Prakam. 2002: 1.
  • 6IAEA. The Radiological Accident in Istanbul. 2001 : 1.
  • 7刘素萍,胡广春,龚建,郝樊华,向永春.模拟核弹头核查中能谱遮盖技术的概念研究[J].物理学报,2001,50(8):1405-1408. 被引量:4