期刊文献+

基于手机的移动式热成像系统研究与初步应用 被引量:3

Investigation on Mobile Phone Based Thermal Imaging System and Its Preliminary Application
在线阅读 下载PDF
导出
摘要 研究了一种基于手机的低成本热成像系统架构及其组成要素:热成像模块、手机与专属操作软件等。探讨了各种阵列热成像模块的设计理念与考虑因素,包含元器件成本与噪声等效温差等。软件中引入了场景变化侦测来改善非均匀修正算法的效率。该系统在积分时间大于16帧的情况下,其噪声等效温差(NETD)可低于150 m K。特别地,将该系统应用于人体运动健康评估中的体温监测上,试验证实了其在医学应用上的可靠性与便利性。 The technical structure of a low-cost thermal imaging which consists of a thermal infrared module and mobile system (TIM) lunched on a mobile phone was investigated, phone and application software. The designing strategies and technical factors toward realizing various TIM array performances are interpreted, including sensor cost and Noise Equivalent Temperature Difference (NETD). In the software algorithm, a mechanism for scene-change detection was implemented to optimize the efficiency of non-uniformity correction (NUC). The performance experiments and analysis indicate that the NETD of the system can be smaller than 150 mK when the integration time is larger than 16 frames. Furthermore, a practical application for human temperature monitoring during physical exercise is proposed and interpreted. The measurement results support the feasibility and facility of the system in the medical application.
出处 《中国医疗器械杂志》 CAS 2015年第3期173-176,共4页 Chinese Journal of Medical Instrumentation
关键词 红外热像仪 手机 移动医疗 非均匀修正算法 无线监测 infrared thermal imaging system, mobile phone, mobile health, non-uniformity correction, wireless monitoring
作者简介 通信作者:刘静,E-mail:jliubme@tsinghua.edu.cn
  • 相关文献

参考文献8

  • 1Tsujino Y. An approach for the performance analysis of an uncooled infrared bolometer imager[J]. Infrared Phys Tech, 2010, 53(1 ): 50-60.
  • 2Kruse PW. Uncooled IR focal plane arrays[J]. Proc SPIE Infrared Technology XXI, 1995, 2552: 556-563.
  • 3Ray SF. Scientific Photography and Applied Imaging[M]. Boston: Focal Press, 1999.46-47.
  • 4Scribner DA, Sarkady KA, Kruer MR, et al. Adaptive nonuniformity correction for IR focal-plane arrays using neural networks[J]. Proc SPIE Infrared Sensors: Detectors, Electronics Signal Process, 1991, 1541: 100-109.
  • 5ASTM. ASTM E1543-00, Standard test method for noise equivalent temperature difference of thermal imaging systems[S].
  • 6How is NEDT measured?[R/OL], http://flir.custhelp.com/app/ answers/detail/a_id/128/-/how-is-nedt-measured%3 F.
  • 7Lim CL, Byrne C, Lee JKW. Human thermoregulation and measurement of body temperature in exercise and clinical settings[J]. Ann Acad Med Singap, 2008, 37(4): 347-353.
  • 8Legrand FD, Bertucci WM, Arfaoui A. Relationships between facial temperature changes, end-exercise affect and during-exercise changes in affect: A preliminary study[J]. Europ J Sport Sci, 2015, 15(2): 161-166.

同被引文献31

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部