期刊文献+

离子色谱法检测牙膏中的亚硫酸盐 被引量:3

Determination of Sulfite in Toothpaste by Ion Chromatography
在线阅读 下载PDF
导出
摘要 建立测定牙膏中亚硫酸盐的离子色谱法.采用Thermo Fisher IonPac AS11–HC 和AG11–HC 色谱柱,在11 mmol/L KOH 溶液中分离测定牙膏中的亚硫酸根离子,亚硫酸根离子的质量浓度与色谱峰面积线性关系良好,线性方程为y=0.114 7x–0.012 3,相关系数r2=0.999 7,检测限为0.025 mg/L,测定结果的相对标准偏差为为2.2%(n=7),回收率在81.8%~90.3% 之间. An ion chromatography method to determine sulfite in toothpastes was established. Separated by ThermoFisher IonPac AS11–HC and AG11–HC chromatographic column with 11 mmol/L KOH solution as mobile phase,sulfitewas determined by ion chromatography. The chromatography peak area showed a good linearity with sulfite concentration(r2=0.999 7), the detectcion limited was 0.025 mg/L,the linear equation was y=0.114 7x–0.012 3,the relative standarddeviation was 2.2%(n=7),and the recoveries were between 81.8% and 90.3%.
出处 《化学分析计量》 CAS 2014年第B12期38-39,共2页 Chemical Analysis And Meterage
关键词 亚硫酸盐 离子色谱 电导 牙膏 sulfite ion chromatography conductivity toothpaste
作者简介 姜振邦;E-mail:Zhenbang.Jiang@Thermofisher.com