期刊文献+

输电线路零序阻抗参数典型抗干扰测量方法的分析与仿真 被引量:9

Analysis and Simulation of Typical Anti-interference Measuring Methods for Zero Sequence Impedance Parameters of Transmission Lines
在线阅读 下载PDF
导出
摘要 输电线路间强电磁耦合造成的干扰严重影响输电线路参数测量的精度。首先,分析了5种典型的输电线路零序阻抗参数抗干扰测量方法的特点及其误差来源,利用PSCAD建立了5种典型抗干扰方法的测量模型,并对各自的测量误差进行仿真,分析了不同情况的干扰对5种抗干扰方法测量结果的影响。随后,设立了两种典型的强干扰环境,分别采用5种抗干扰方法进行测量,通过仿真结果的对比,得到了两种情形下5种抗干扰方法的测量误差大小排序。最后,分析了被测线路分别为停电线路和运行线路时,测量仪器分辨率对5种抗干扰方法的影响。研究结果可为强干扰环境下输电线路零序阻抗参数抗干扰测量方法的选取提供参考。 The interference caused by strong electromagnetic coupling between transmission lines seriously affects the measurement accuracy of impedance parameters of transmission line.Firstly,the characteristics and error sources of five typical zero sequence parameter anti-interference measurement methods for transmission lines are analyzed.The measurement models of the five typical measurement methods are established by using PSCAD,and their measurement errors are simulated separately.The influence of different conditions on the measurement results of five typical measurement methods is analyzed.Then,two typical strong interference environments are set up,and five anti-interference measurement methods are used to measure,respectively.By the comparison of the simulation results,the order of the measurement errors of the five antiinterference methods in the two cases is obtained.Finally,the effect of the measuring instrument resolution on the measurement methods is analyzed when the measured line is withdrawn from normal operation and under normal operation,respectively.The results of this study can provide a reference for the selection of anti-interference measurement methods for transmission line impedance parameters in strong interference environment.
作者 胡志坚 傅晨宇 倪识远 罗福玲 HU Zhijian;FU Chenyu;NI Shiyuan;LUO Fuling(School of Electricai Engineering,Wuhan University,Wuhan 430072,China)
出处 《电力系统自动化》 EI CSCD 北大核心 2018年第23期174-183,共10页 Automation of Electric Power Systems
关键词 输电线路 电磁耦合 零序阻抗参数 抗干扰方法 测量误差 transmission line electromagnetic coupling zero sequence impedance parameters anti-interference methods measurement error
作者简介 胡志坚(1969-),男,通信作者,博士,教授,博士生导师,主要研究方向:电力系统稳定分析与控制、新能源接入与分布式电力系统、输电线路参数带电测量等。E-mail:zhijian_hu@163.com;傅晨宇(1992-),男,硕士研究生,主要研究方向:输电线路参数带电测量。E-mail:2015202070075@whu.edu.cn;倪识远(1992-),男,硕士研究生,主要研究方向:输电线路参数带电测量。E-mail:shiyuan_ni@whu.edu.cn
  • 相关文献

参考文献19

二级参考文献249

共引文献350

同被引文献80

引证文献9

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部