期刊文献+

催化氧化处理酸性染料废水 被引量:7

The Acidic Dye Wastewater Treatment by Inside - electrolytic——Catalysis and Oxidation
在线阅读 下载PDF
导出
摘要 研究了二氧化氯(ClO2)和芬顿试剂(Fe2+/H2O2)两种氧化体系对经微电解预处理的染料废水降解的最佳工艺条件,包括pH、时间、剂量。实验发现在氧化剂低剂量且无絮凝剂时,混凝前两种氧化体系对废水的降解率差不多,混凝后或高剂量时芬顿试剂对废水的处理效果更好。 The optimal processing condition of chlorine dioxide and Fenton s reagent used on dye wastewater which was pretreated with inside - electrolytic catalysis and oxidation has been studied. It concluded pH values, time and dosage. The experimental results showed that on the condition of few oxidation accelerator dosage and without coagulant , the degradation degree of these two oxidation systems on wastewater treatment is about equal , but Fenton's reagent has a great advantage over chlorine dioxide on the contrary condition of above.
出处 《上海化工》 CAS 2001年第23期4-6,15,共4页 Shanghai Chemical Industry
关键词 催化氧化 酸性染料废水处理 微电解 二氧化氯试剂 芬顿试剂 Inside - electrolytic Chlorine reagent Fenton' s reagent Catalysis and oxidation