摘要 目的探讨肱骨干骨折使用锁定钢板术后失败原因。方法回顾4例肱骨骨折锁定钢板固定后钢板断裂、螺钉拔出及不愈合的原因,其中钢板断裂2例,螺钉拔出1例,不愈合1例,均给予相应二次手术治疗。结果二次手术后均骨性愈合。结论术后患者过早大强度活动、固定材料选择不当等原因是导致锁定钢板固定术后失败的主要原因。 Objective To explore the failure causes of plate fixation operation. Methods Causes of operation failure in four patients with humeral fracture were retrospectively analyzed. Two patients were of steel plate fracture,one case was of bolt off and one case was of bone nonunion. All the 4 cases were received reoperation. Results After reoperation,all the 4 cases resulted in bony union. Conclusion Untimely hard intensity activities after operation and wrong choice of fixation material are the major cause leading to the failure of locking plate fixation operation.
作者 柳辑章
出处 《职业卫生与病伤》 2014年第2期123-124,共2页 Occupational Health and Damage
关键词 锁定钢板 内固定 肱骨干骨折. locking plate internal fixation humeral fracture
作者简介 柳辑章(1978-),男,本科,主治医师,骨科创伤
  • 相关文献

参考文献2

二级参考文献4

共引文献10

同被引文献52

  • 1Hettrich CM,Neviaser A,Beamer BS,et al.Locked plating of the proximal humerus using an endosteal implant.J Orthop Trauma.2012;26(4):212-215.
  • 2Euler SA, Hengg C,Wambacher M,et aI.Allogenic bone grafting for augmentation in two-part proximal humeral fracture fixation in a high-risk patient population.Arch Orthop Trauma Surg.2015; 135(1 ):79-87.
  • 3Gross RH.The use of bone grafts and bone graft substitutes in pediatric orthopaedics: an overview.J Pediatr Orthop.2012;32(1 ): 100-105.
  • 4lannotti JP, Williams GR.Disorders of the shoulder: diagnosis and mangement. Philadelphia: Lippinccott Williams & Wilkins, 1999:1015-1016.
  • 5Gardner MJ,Boraiah S,Helfet DL,et al.lndirect medial reduction and strut support of proximal humerus fractures using an endosteal implant.J Orthop Trauma 2008;22(3):195-200.
  • 6Lee CW, Shin SJ.Prognostic factors for unstable proximal humeral fractures treated with locking-plate fixation.JSES.2009; 18(1 ):83-88.
  • 7Neviaser AS,Hettrich CM,Beamer BS,et aI.Endosteal strut augment reduces complications associated with proximal humeral locking plates.Clin Orthop Relat Res.2011 ;469( 12): 3300-3306.
  • 8Matassi F, Angeloni R,Carulli C,et al.Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus.Injury.2012;43(11 ): 1939-1942.
  • 9Mathison C,Chaudhary R,Beaupre L,et al. Biomechanical analysis of proximal humeral fixation using locking plate fixation with an intramedullary fibular allograft.Clin Biomech (Bristol,Avon).2010;25(7) 642-646.
  • 10Berkes MB,Little MTM,Lazaro LE,et al.lntramedullary allograft fibula as a reduction and fixation tool for treatment of complex proximal humerus fractures with diaphyseal extension.J Orthop Trauma.2014;28(3): e56-e64.