期刊文献+

化学沉淀法处理模拟含铜废水的研究 被引量:31

Research on Treatment of Simulated Wastewater Containing Copper by Chemical Sedimentation Method
在线阅读 下载PDF
导出
摘要 采用化学沉淀法对模拟含铜废水进行处理,分别考察了反应pH值、温度、沉淀时间、絮凝剂(PAM)用量以及PAM作用下沉淀时间等因素对模拟含铜废水处理的影响,并在最佳条件下对实际含铜废水进行了处理研究。结果表明,采用化学沉淀法处理200 mg/L的模拟含铜废水时,1‰聚丙烯酰胺(PAM)的最佳加入比例为30 mg/L,在25℃下,合适的pH值为7.12左右,沉淀时间13 min。在此条件下对来自葫芦岛锌厂的酸性平均含铜为167 mg/L的实际废水继续处理,处理后废水中铜离子浓度平均值为0.87 mg/L,可以实现实际废水中铜离子的有效去除。 Chemical sedimentation method was used in treating the simulated wastewater containing copper.The effects of pH value,temperature,quantity of flocculant(PAM),sedimentation time(before and after adding PAM) on wastewater treatment were studied,and the wastewater was treated at the optimal parameter.Results showed that,in treating the wastewater containing 200 mg/L copper with chemical sedimentation method at 25 ℃,the appropriate dosage of PAM(1‰) was 30 mg/L,pH value was 7.12 and sedimentation time was 13 min.Under the optimum conditions,the acid wastewater from Huludao Zinc Plant with an average copper concentration of 167 mg/L was treated,and the copper concentration in effluent was 0.87 mg/L,which can remove copper in actual wastewater efficiently.
出处 《环境保护科学》 CAS 2014年第2期35-38,共4页 Environmental Protection Science
关键词 含铜废水 化学沉淀法 去除效果 Copper Wastewater Chemical Sedimentation Method Removal Efficiency
作者简介 熊英禹(1975-),男,工程师.研究方向:环境管理.
  • 相关文献

参考文献12

二级参考文献37

共引文献40

同被引文献288

引证文献31

二级引证文献195

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部