600MW机组轴流一次风机选型分析与节能改造

Study on Lectotype Margin and Energy-saving Retrofit of Primary Air Axial-fan for 600MW Unit
在线阅读 下载PDF
导出
摘要 对部分600 MW机组的动叶可调轴流式一次风机进行了调研,分析后得知,对于一次风机存在选型偏大、电机容量与风机容量不匹配等问题.依据风机的设计规范,并考虑各煤种掺烧的普遍情况,对于一次风机选型的流量裕度可控制在30%~40%,电机功率可控制在约2 000 kW.从节能方面考虑,对于选型偏大、调峰范围较大机组的一次风机,可考虑进行变频改造. According to the investigation of equipment code and practical operation state of primary air axial-fan with regulation of moving blades for some 600 MW power plants, the lectotype margin of those were larger, and the electric motor didn't match them well. And it was suggested that the rate of flow lectotype margin of primary air fan with regulation of moving blades shall be controlled between 300/oo and 400/oo. The power of motor shall be within 2 000 kW based on design specification and combustion of mixed coal. Besides, the frequency conversion retrofit was proposed for the primary air fan which of the rate of flow lectotype margin was larger.
出处 《电站辅机》 2014年第1期39-44,共6页 Power Station Auxiliary Equipment
关键词 机组 风机 轴流式 动叶 可调 选型裕度 功率 变频 unit primary air fan moving blades regulated lectotype margin motor power frequency conversion
作者简介 宁新宇(1981-),男,硕士,工程师,从事电厂节能和制粉系统运行优化等方面的技术工作.
  • 相关文献

参考文献12

二级参考文献14

  • 1刘家钰.我国电站风机的节能途径探讨[J].风机技术,2007,49(3):50-55. 被引量:19
  • 2DL5000-2000火力发电厂设计技术规程[S].北京:中国电力出版社.2001.
  • 3郭立君,何川.泵与风机(第3版)[M].北京:中国电力出版社,2008.
  • 4郑体宽.热力发电厂[M].北京:水利电力出版社,1997.
  • 5韩平 邹文华.变频调速改造试验研究总报告[R].河南电力试验研究所,2001..
  • 6邢希东.600MW火电机组降低厂用电率措施[J].中国电力,2007,40(9):60-64. 被引量:45
  • 7郭立君.泵与风机(第二版)[M].北京:中国电力出版社,1996.
  • 8节约年活动方案[R].天津大唐国际盘山发电有限责任公司,2007.
  • 9刘家珏.电站风机改造与可靠性分析[M].北京:中国电力出版社,2002.
  • 10R. Moog,N. Müller. Technical aspects and performance in collecting peripheral blood progenitor cells[J] 1998,Annals of Hematology(4):143~147