期刊文献+

注射液中微粒大小的非接触式测定

Non-contact Measurement of Particles in Injection
在线阅读 下载PDF
导出
摘要 研究非接触式杂质颗粒的测量,解决常规注射药品中微粒杂质的抽样问题,并进行客观的品定。系统采用CCD相机成像技术,基于运动物体的检测以及嵌入式系统的结合,并采用VC++作为编程主平台,经过多次试验,对于40μm和60μm的国标粒子检测结果一致性比较好,解决了人肉眼长时间观察显微图像因疲劳容易造成的主观判断失误。 We probed into the non-contact measurement of particles in inj ection to solve the sam-pling problem of impurity in particles of massive inj ection.The measuring system is based on the technology of CCD imaging,mobile-obj ect detection and embedded system with VC++ as the main programming platform.Experiments show that the system has a good performance in the measurement of 40μm and 60μm international particles.It can reduce subjective errors caused by the fatigue of human eyes after a long time of microscopic observation.
出处 《淮海工学院学报(自然科学版)》 CAS 2014年第1期19-21,共3页 Journal of Huaihai Institute of Technology:Natural Sciences Edition
关键词 非接触式 微粒测量 运动物体 嵌入式系统 non-contact particle measurement mobile obj ects embedded system
作者简介 于洪雨(1984一).男.江苏连云港人,江苏省灌南县中跃院信息科工程师,主要从事医疗器械开发与维护方而的研究,(E—maid26974873@163.com.
  • 相关文献

参考文献5

  • 1周鑫玲,曲丹丹,俞岳,何阳.微型计算机在微粒检测中的应用[J].仪器仪表学报,1998,19(4):445-448. 被引量:2
  • 2王占全,徐慧.VisualC++数字图像处理技术与工程案例[M].北京:人民邮电出版社,2011.
  • 3OpenCVChina中文网站.运动分析与对象跟踪[EB/OL].[2013-12-20].http://wiki.opencv.org.cn/in-dex.php/cv.
  • 4窦振中,汪立森.PIC系列单片机的应用设计与实例[J].北京:北京航空航天大学出版社,1999.
  • 5湖广书.数字信号处理[M].北京:清华大学出版社,2003.

二级参考文献2

  • 1高玉成,药物分析杂志,1995年,增刊,31页