摘要 在某回转轴系上建立了一系列坐标系 ,通过坐标系之间的姿态关系分别推导了用水平仪测试法和自准直光管测试法测试主轴轴系倾角回转误差时水平仪和光管的读数表达式。根据水平仪和自准直光管读数中的各个误差组成部分和倾角回转误差在它们中的表达式的区别 ,得出了水平仪法能测试出主轴回转误差中的一次谐波成分 。 A series of coordinate systems is set up on a perpendicular axis,and by the attitude relations among coordinate systems,the equations of readouts of the level instrument and the autocollimator are deduced when they areused to measure the wobble error of the axis system.The deduced equations consist of many kinds of errors.From the differences of the wobble errors in their equations,the conclusion that level instrument can measure the first harmonic wobble error,while the autocollimator can not measure the first harmonic wobble error is drawn.
机构地区 哈尔滨工业大学
出处 《中国惯性技术学报》 EI CSCD 2000年第3期74-78,共5页 Journal of Chinese Inertial Technology
关键词 倾角回转误差 水平仪 自准直光管 竖直轴系 wobble error level instrument autocollimator
  • 相关文献

参考文献1

二级参考文献4

同被引文献41

  • 1焦贵福.机床回转轴回转精度的评价方法[J].组合机床与自动化加工技术,1993(5):10-20. 被引量:3
  • 2任顺清,王俊柱.用水平仪测试倾角回转误差的数据处理[J].哈尔滨工业大学学报,2006,38(6):837-839. 被引量:13
  • 3GJB 1801-93,惯性技术测试设备主要性能试验方法[S].
  • 4颜景平.主轴回转误差测量及其消偏问题[J].东南大学学报(自然科学版),1984,2:5-10.
  • 5罗海燕,翟超,金熠.回转误差测量新方法的研究[J].电子测量与仪器学报,2008,(5):10-13.
  • 6H T Yau. Evaluation and uncertainty analysis of vec- torial Tolerances[J]. Precision Engineering, 2000, 20 : 22-28.
  • 7杨慧哲.基于自准直仪的转轴倾角回转误差测量精度分析[C].长沙:2013光学年会论文集,2013.
  • 8Robert W Mitchell. A composite pointing error analysis of a five-axis flight/target motion simula- tor with an infrared scene projector[J]. SPIE,2006, 6208:1-10.
  • 9惯性技术测试设备主要性能试验方法.中华人民共和国国家军用标准[S].GJB1801-93.
  • 10杨云涛,石志勇,关贞珍,李豫泽.地磁场在导航定位系统中的应用[J].中国惯性技术学报,2007,15(6):686-692. 被引量:37

引证文献7

二级引证文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部