摘要
将流动注射分析法与二苯碳酰二肼分光光度法联用,以混酸溶液做载流,建立电镀废水中铬(V1)的流动注射全自动在线分析方法.实验考察酸度、显色剂用量等影响因素,并确定了最佳管路.结果表明:所建立方法的线性范围为0.02~4.0mg·L^-1。相关系数R^2为0.9996,检出限为0.02mg·L^-1,标准加入回收率为97.04%,相当标准偏差为0.09%~0.91%(n=5).
A new method, named flow injection automatic online analysis, was developed for the determination of hexa- valent chromium using mixed acid solution as carrier flow in electroplating wasterwater. This method combined the flow injection analysis and diphenylcarbohydrazide spectrophotometry method. Influencing factors such as acidity, addition a- mount of chromogenic agent were investigated, and the optimum piping was obtained. A linear range of 0. 02-4. 0 mg· L^-1 with good correlation coefficient (R2 =0. 999 6) was obtained for chromium determination, and the detection limit of this method was 0. 02 mg· L^-1. The recovery was 97.04% and the RSD ranged from 0. 09% to 0. 91% (n=5).
出处
《华侨大学学报(自然科学版)》
CAS
北大核心
2013年第6期687-690,共4页
Journal of Huaqiao University(Natural Science)
基金
福建省厦门市科技计划项目(3502Z20103034)
关键词
流动注射分析法
铬(VI)
电镀废水
二苯碳酰二肼
分光光度法
flow injection analysis
chromium (VI)
electroplating wastewater
diphenylcarbohydrazide
spectrophotom-etry
作者简介
通信作者:薛秀玲(1975-),女,副教授,主要从事环境分析化学及水处理工程的研究.E-mail:xiulingxue@163.com.