摘要
试验采用有效体积为7.0 m3的SBR中试反应器处理生活污水,考察了低温条件下短程深度脱氮工艺的启动方法及稳定性.利用基于鼓风机频率(BF)和pH的实时控制策略对SBR系统进行实时控制.结果表明,SBR系统在低温条件(11~16℃)和50 d内快速启动短程深度脱氮工艺,亚硝酸盐积累率从19.8%上升到90%.在中低温条件(9~28℃)下短程深度脱氮性能维持长达550 d,亚硝酸盐积累率始终维持在95%左右,出水TN浓度维持在3 mg·L-1,TN去除率维持在95%以上.由此可见,低温下启动SBR短程深度脱氮工艺并长期维持完全可行.
In order to test the start-up and maintain method for short-cut advanced nitrogen removal process at low temperature,this study used a pilot-scale SBR process with a working volume of 7.0 m3 to treat domestic wastewater.Real-time control strategy based on blower frequency(BF) and pH was applied to control the pilot-scale SBR process.Results showed that short-cut nitrification process achieved within 50 days at low temperature(11-16℃),and the nitrite accumulation rate(NAR) of SBR process increased from 19.8% to 90%.Short-cut nitrification process in pilot-scale SBR was maintained for as long as 550 days in the temperature range of 9-28℃,and NAR was maintained above 95%.Meanwhile,the total nitrogen(TN) in effluent was 3 mg·L-1 and the TN removal efficiency was above 95%.Therefore,it is feasible to start-up and maintain the short-cut advanced nitrogen removal process under low temperature condition in the SBR process.
出处
《环境科学》
EI
CAS
CSCD
北大核心
2013年第8期3164-3170,共7页
Environmental Science
基金
国家水体污染控制与治理科技重大专项(2012ZX07302-001-04-01)
北京市属高等学校人才强教计划项目(PHR20090502)
关键词
低温启动
中试SBR
短程硝化反硝化
实时控制
长期维持
start-up at low temperature pilot-scale SBR short-cut nitrification process real-time control long term maintenance
作者简介
顾升波(1982-),男,博士,主要研究方向为污水生物处理及过程控制,E—mail:gushengbo@bmedi.cn