地源热泵系统与传统空调系统形式相比增加了地热换热器,地热换热器的合理长度对整个热泵系统的性能有着重要作用。文章讨论了竖直U型埋管的传热模型,得出地下埋管换热器的热阻表达式。利用Matlab语言对地埋管换热器准三维模型进行计算机语言编译,得出地埋管长度计算方法。
Ground-source heat pump systems compared with traditional forms of air conditioning system increased geothermal heat exchangers, reasonable length of geothermal heat exchangers for heat pump system performance as a whole has an important role, The heat transfer model for vertical U-tuble ground was discussed, and expressions of thermal resistance of buried tube heat exchanger were drawn. With the help of Matlab computer language, the three-dimensional model of buried tube heat exchanger was compiled, and the buried pipe length calculations were concluded.
出处
《建筑热能通风空调》
2013年第2期70-73,共4页
Building Energy & Environment
关键词
地热换热器竖直埋管传热研究设计计算
geothermal heat exchangers, vertical buried pipe, heat transfer research, estimated design
作者简介
徐建军(1986-),男,硕士研究生;山东省济南市历城区山东建筑大学热能工程学院(250101);E—mail:xujianjun521521@126.com