CBCT测量磨牙根管工作长度的实验研究 被引量:20

Measure the Root Canal Length of Molar in Vitro by CBCT
在线阅读 下载PDF
导出
摘要 目的:评价CBCT测量根管工作长度的准确性,为临床应用提供实验依据。方法:选取外形完整、根尖发育完成或接近完成、无龋坏、无充填及牙髓病治疗史的上下颌磨牙40颗(共计136个根管)。应用CBCT测量各磨牙根管工作长度,以直视下测量的根管工作长度为标准,判断测量方法的准确性,并且和RVG、根管长度电测仪测量结果比较。结果:CBCT(根管腔测量法;根长度测量法)的准确率分别是84.56%、91.91%,而RVG、根管长度电测仪的准确率分别是58.09%、86.03%。经统计学检验,CBCT测量的准确率与根管长度电测仪差异无统计学意义(P>0.05),RVG测量与其他两种方法的准确率差异有统计学意义(P<0.01)。结论:CBCT与根管长度电测仪测量磨牙根管工作长度的准确率均较高,但各有其优缺点,CBCT可作为临床根管测量方法的一种有效的补充,而在RVG图像上测量根管长度的准确率不高。 Objective: Evaluate the accuracy of measuring root canal working length by CBCT in order to provide the proof for the clinical work. Methods: Collected 40 mandibular and maxillary molars (a total of 136 root canals) between November 2011 to January 2012, which extracted at our hospital because of the requirement of the treatment, with the complete contour, the mature apical stomata, non-caries, non-filling and non-endodontic treatment history. The length of the extracted teeth root canal measured under direct vision was granted as the criterion to compare the measuring accuracy of the CBCT, the RVG and the electronic apex locator (EAL). Provide a reference for selecting quantitative methods of measuring the root canal working length in clinical. Results: CBCT (root lumen measurement; root length measurement accuracy of the method) are 84.56%, 91.91%, RVG, the electronic apex locator (EAL) accuracy rate is 58.09%, 86.03%. The statistical test the CBCT and the EAL accuracy difference was not statistically significant (P 〉 0.05), RVG measurement accuracy rate differences with the other two methods was statistically significant (P 〈 0.01). Conclusion: The results of the EAL and CBCT is the most accurate, the RVG result is the worst. The CBCT can be considered as an effective complement to the commonly clinical methods.
出处 《CT理论与应用研究(中英文)》 2013年第1期173-179,共7页 Computerized Tomography Theory and Applications
关键词 根管工作长度 磨牙 CBCT root canal working length molar CBCT
作者简介 张以鸣(1981-),男,同济大学附属第十人民医院住院医师,日本松本齿科大学在读博士,主要从事口腔临床工作和研究,Tel:021-66301727,E-mail:zym811113@hotmail.com唐小山(1970-),男,同济大学附属第十人民医院口腔科副主任医师,主要从事口腔正畸临床与研究,Tel:021—66301731,E-mail:tangrong200l@hotmail.com。
  • 相关文献

参考文献15

  • 1樊明文.牙体牙髓病[M].2版.北京:人民卫生出版社,2003: 245-250.
  • 2楼滨徐.电测法确定根尖孔位置的临床疗效评价[J].口腔医学,2007,27(4):221-222. 被引量:7
  • 3Taylor C, Geisler TM, Holden DT, et al. Endodontic applications of cone-beam volumetrictomography[J]. Journal of Endodontics, 2007, 33: 1121-32.
  • 4唐小山,房莉,曾飞煌,袁顾军,徐远志.CBCT技术在多生牙诊断中的意义[J].CT理论与应用研究(中英文),2012,21(2):329-334. 被引量:19
  • 5Aurelio JA, Nahmias Y, Gerstein H. A modle for demonstrating an electronic canal-lengthmeasuring device[J]. Journal of Endodontics, 1983, 9(12): 568-569.
  • 6Kuttler Y. Microscopic investigation of root apexes[J]. Journal of the American DentalAssociation, 1955,50(5): 544-552.
  • 7Ebrahim AK,Wadachi R, Suda H. In vitro evaluation of accuracy of five different electronicapex locators for determining the working length of endodontically retreared teeth[J].Australian Endodontic Journal, 2007, 33(1): 7-12.
  • 8Lagravere M0, Carey J, Toogood RW, et al. Three-dimensional accuracy of measurements madewith software on cone-beam computed tomography images [J]. American Journal of Orthodonticsand Dentofacial Orthopedics, 2008, 134(1): 112-116.
  • 9Stratemann SA, Huang JC, Maki K, et al. Comparison of cone-beam computed tomography imagingwith physical measures[J], Dentomaxillofac Radiology, 2008, 37(2): 80-93.
  • 10Lopes PM, Moreira CR, Perrella A, et al. 3~D volume rendering maxillofacial analysis ofangular measurements by multislice CT[J]. Oral Surgery, Oral Medicine, Oral Pathology, OralRadiology and Endodontics, 2008, 105(2): 224-230.

二级参考文献16

  • 1韩本谊,江笑露,李宏儒.螺旋CT扫描在牙齿正畸中的临床应用价值[J].中华放射学杂志,2005,39(2):161-164. 被引量:34
  • 2陈雨雪,陈铀,郭杰,陈扬熙.CT三维重建在正畸埋伏牙诊断中的应用[J].华西口腔医学杂志,2005,23(5):410-411. 被引量:29
  • 3李然,石四箴.牙科三维CT对上颌乳磨牙根分叉水平面根管的研究[J].山西医药杂志,2007,36(1):39-40. 被引量:5
  • 4Lozano A,Forner L,Llena C,et al.In vitro comparison of root -canal measurements with conventional and digital radiology.International Endodontic Journal,2002,35(6):542-500.
  • 5Mouyen F,Benz C,Sonnabend E,et al.Presention and physicalevaluation of Radio Visio Graphy.Oral Surg Oral Med Oral Pathol,1989,68:42-238.
  • 6Thanyakam C,Hansen K,Rohlin M,et al.Measurements of tooth lengh in panoramic radiographs:the use of indications.Dento Maxillo Facial Radiology,1992,21 (1):26-30.
  • 7Stramotas S,Geenty JP,Petocz P,et al.Accuracy of linear and angular measurements on panoramic radiographs taken at various positions in vitro.Eur J Orthod,2002,24 (1):43-52.
  • 8Loushine RJ,Weller RN,Kimbrough WF,et al.Measurement of endodontic file lengths:calibrated versus uncalibrated digital images.Journal of Endodontics,2001,27 (12):779-781.
  • 9Hashimoto K, Arai Y, Iwai K, et al. A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine[J]. Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2-3, 95: 371-377.
  • 10Lagravere MO, Carey J, Toogood RW, el al. Three-dimensional accuracy of measurements made with software on cone-beam computed tomography images[J]. Am J Orthod DentofaciaL Orthop, 2008, 134(1): 112-116.

共引文献31

同被引文献210

引证文献20

二级引证文献110

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部