期刊文献+

三峡水库蓄水以来近坝区水温垂向结构分析 被引量:28

Analysis of the vertical structure of water temperature in the vicinity area of Three Gorges Dam since the Three Gorges Reservoir impounds
原文传递
导出
摘要 以三峡大坝上游距离最近的庙河断面作为典型断面,利用2004—2011年实测水温资料,分析三峡水库近坝区水域水温垂向结构。分析结果表明:庙河断面从2006年开始,在水库底部一定高度内,每年4—6月份水体水温在垂向上均会出现一定的温差,但该区域还没有形成稳定温跃层;温差较大的区域均出现在水深75m以下,该区域均位于电站取水口高程(110m)以下,其水温对三峡水库下泄水流水温没有影响;三峡水库不存在深层低温水下泄问题。 Miaohe section upstream closest to Three-Gorges Dam was taken as a typical cross-section.Based on the measured temperature data in 2004—2011,the vertical structure of water temperature in the vicinity area of Three Gorges Dam has been analyzed.The results show that it has not yet formed the thermocline in the vicinity area of the Three Gorges Dam;the regions of the large temperature gradient(75m)are located below the elevation of the power plant intake(110m);the water in the region with large temperature gradient has not effected on the discharged flow from the Three Gorges Reservoir;at present there are no low-temperature flow in the bottom layer discharged from the Three Gorges Reservoir.
出处 《水利学报》 EI CSCD 北大核心 2012年第10期1254-1259,共6页 Journal of Hydraulic Engineering
基金 国家自然科学基金资助项目(51009081) 国家杰出青年基金(50925932) "十一五"国家科技支撑计划项目(2008BAB29B09)
关键词 三峡水库 水温场结构 低温水流 Three Gorges Reservoir structure of water temperature field low-temperature flow