期刊文献+

双扇区重建中时相一致性对冠状动脉CT血管成像中血管显示的影响 被引量:5

Influence of Data Consistency on Image Quality of Coronary CT Angiography with Bi-sector Reconstruction
在线阅读 下载PDF
导出
摘要 目的通过模拟冠状动脉CT血管成像(CTA)中应用双扇区重建时心率变化可能导致的时相错位,评价双扇区重建中时相一致性对冠状动脉显示的影响。资料与方法30例患者采用回顾性心电门控扫描行冠状动脉CTA检查,对右冠状动脉垂直走行段行图像重建,包括:①75%单扇区重建;②75%双扇区重建;③前一个心动周期以R-R间期75%为中心,后一个心动周期分别以69%、72%、78%、81%为中心进行双扇区重建。选择各次重建均包含的3个轴面,从血管中心密度、面积、形态(横、纵径比值)、边缘锐利度评价冠状动脉显示情况。结果①75%双扇区重建与75%单扇区重建比较,各参数差异均无统计学意义(P>0.05);②其余各次双扇区重建分别与75%单扇区重建比较,各参数差异均有统计学意义(P<0.05),且差异随时相间隔增大而增大。结论双扇区重建中时相一致性是保证重建图像准确性的关键因素,心率变化导致的时相差可以改变所显示冠状动脉的形态和特征,并进而可能造成对冠状动脉狭窄评价的偏差。 Purpose To evaluate the influence of data consistency on image quality of coronary CT angiography(CTA) with bi-sector reconstruction,by simulating phase mismatch that may occur in patients with arrhythmia.Materials and Methods 30 cases with normal findings on coronary CTA using ECG gated spiral scan were included.Targeted retrospective reconstructions of the vertical portion of right coronary artery were performed including half-reconstruction at 75% R-R interval,bi-sector reconstruction at 75%,bi-sector reconstructions with data centered 75% of the first cardiac cycle and those centered at 69%,72%,78% and 81% of the second cardiac cycle respectively.Three slices reconstructed with bi-sector reconstruction algorithm in all bi-sector reconstructions were used for analysis in each case.Central density of vessel enhancement,cross-sectional area,shape of vessel(depicted by ratio of long axis/short axis) and sharpness of vessel margin were analyzed to evaluate image quality.Results ① There was no significant difference between the parameters with half reconstruction and bi-sector reconstruction at 75% R-R interval(P0.05).② The parameters with all other bi-sector reconstructions were significantly different from those with half reconstruction(P0.05),while the difference increased as the phase mismatch increasesd.Conclusion Phase matching is critical to the accuracy of CTA in bi-sector reconstruction.Mismatch caused by heart rate variation may lead to alteration of the characteristics of coronary artery,with possible subsequent bias on stenosis evaluation.
出处 《中国医学影像学杂志》 CSCD 北大核心 2012年第10期725-728,733,共5页 Chinese Journal of Medical Imaging
基金 国家自然科学基金项目(30970821)
关键词 冠状动脉疾病 冠状血管造影术 体层摄影术 螺旋计算机 图像处理 计算机辅助 Coronary artery disease Coronary angiography Tomography spiral computed Image processing computer-assisted
作者简介 通讯作者杜祥颖
  • 相关文献

参考文献15

  • 1朱巧洪,曾庆思,孙翀鹏,林翰菲,岑人丽,张超亮,刘莉.服用硝酸甘油对多层螺旋CT冠状动脉成像的影响[J].中华放射学杂志,2007,41(8):809-812. 被引量:24
  • 2韩静,陈喜中,王峰,郭富强.MSCT冠状动脉血管成像不同重组技术的比较[J].放射学实践,2007,22(1):82-84. 被引量:6
  • 3Herzog C, Nguyen SA, Savino G, et al. Does two- segment image reconstruction at 64-section CT coronary angiography improve image quality and diagnostic accuracy? Radiology, 2007, 244(1): 121-129.
  • 4Schoepf U J, Zwerner PL, Savino G, et al. Coronary CT angiography. Radiology, 2007, 244(1): 48-63.
  • 5Nieman K, Cademartiri F, Lemos PA, et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation, 2002, 106( 16): 2051-2054.
  • 6Schroeder S, Kopp AF, Kuettner A, et al. Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: experience in 94 patients. Clin Imaging, 2002, 26(2): 106-111.
  • 7Becker CR, Ohnesorge BM, Schoepf U J, et al. Current development of cardiac imaging with multidetector-row CT. Eur J Radiol, 2000, 36(2): 97-103.
  • 8Leschka S, Wildermuth S, Boehm T, et al. Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology, 2006, 241(2): 378-385.
  • 9Wintersperger B J, Nikolaou K, von Ziegler F, et al. Imagequality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed. Invest Radiol, 2006, 41(5): 436-442.
  • 10孙钢,李敏,李国英,丁娟,李胜辉.320排容积CT冠状动脉血管成像心率与重组时相对图像质量的影响[J].中华医学杂志,2011,91(1):5-10. 被引量:19

二级参考文献53

共引文献71

同被引文献27

  • 1陈月芹,孙占国,王林省,史志涛,贾存玮,张谷青,张新东,王彦辉,李慧,王玉红.前瞻性心电门控技术在双源CT冠状动脉成像中的应用价值[J].医学影像学杂志,2012,22(2):178-181. 被引量:8
  • 2王锡明,武乐斌,李振家,柳澄,陈海松.64层螺旋CT在冠状动脉造影中的应用[J].中华放射学杂志,2005,39(11):1201-1204. 被引量:151
  • 3Pugliese F, Mollet NR, Runza G, et al. Diagnostic accuracy of nonin- vasive 64-slice CT coronary angiography in patients with stable angi- na Dectoris. Eur Radio1.2006.16,575.
  • 4Raff GL, Gallagher MJ, O "Neil WW, et al. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am CollCardiol,2005 ,46 :552.
  • 5Hoffmann MH,Shi H,Manzke R,et al. Noninvasive coronary angiog- raphy with 16-detector row CT:effect of heart rate. Radiology,2005, 234 : 86.
  • 6Wintersperger BJ, Nikolaou K, von Ziegler F, et al. Image quality, motion artifacts, and reconstruction timing of 64-slice coronary com- puted tomography angiography with 0.33-second rotation speed. In- vest Radiol,2006 ,41:436.
  • 7Becker CR, Ohnesorge BM, Schoepf UJ, et al. Current development of cardiac imaging with multi detector-row CT. Eur J Radiol, 2000, 36 ..97.
  • 8Flohr TG, McCollough CH, Bruder H, et al. First performance evalua- tion of a dual-source CT (DSCT) system. Eur Radiol,2006 ,16 :256.
  • 9Halliburton SS, Stillman AE, Flohr T, et al. Do segmented recon- struction algorithms for cardiac multi-slice computed tomography im- prove image quality .9 Herz,2003,28 : 20.
  • 10Herzog C, Nguyen SA, Savino G, et al. Does two-segment imagere- construction at 64-section CT coronary angiography improve image quality and diagnostic accuracy? Radiolo'v.2007.244,121.