摘要 In this paper, wind velocities and directions (sea and land) are recorded in different days and times. The data collected were compared with the weather data from the Brunei Darussalam Meteorological Service (BDMS) and the findings of other researchers and were found to be in good agreement. The potential of wind energy is predicted from the available data collected. The average generated power (forenoon and afternoon) is found to be 25 (mean) and 18W (median), 101 (mean) and 73W (median), 912 (mean) and 660 W (median), 10137 (mean) and 7331 W (median) for a rotor with a diameter of 2.5, 5, 15 and 50 m, respectively. The power density Pd for wind farming is found to be 0.26 (mean) and 0.19 (median), 0.31 (mean) and 0.22 (median) for the rotor whose diameter is 2.5 and 50 m, respectively, while the average Pd values are found to be 0.28 (mean) and 0.2 (median) for the rotor whose diameter is 5 and 15 m. In this paper, wind velocities and directions (sea and land) are recorded in different days and times. The data collected were compared with the weather data from the Brunei Darussalam Meteorological Service (BDMS) and the findings of other researchers and were found to be in good agreement. The potential of wind energy is predicted from the available data collected. The average generated power (forenoon and afternoon) is found to be 25 (mean) and 18W (median), 101 (mean) and 73W (median), 912 (mean) and 660 W (median), 10137 (mean) and 7331 W (median) for a rotor with a diameter of 2.5, 5, 15 and 50 m, respectively. The power density Pd for wind farming is found to be 0.26 (mean) and 0.19 (median), 0.31 (mean) and 0.22 (median) for the rotor whose diameter is 2.5 and 50 m, respectively, while the average Pd values are found to be 0.28 (mean) and 0.2 (median) for the rotor whose diameter is 5 and 15 m.
出处 《Frontiers in Energy》 SCIE CSCD 2012年第3期275-279,共5页 能源前沿(英文版)
关键词 wind velocity TEMPERATURE tower height power density Raleigh distribution electrical power wind velocity, temperature, tower height,power density, Raleigh distribution, electrical power
作者简介 E-mail: abdus.salam@itb.edu.bn
  • 相关文献

参考文献7

  • 1Boukhezzar B,Siguerdidjane H,Hand M M. Non-linear control of variable speed wind turbines for generator torque limiting and power optimization[J].ASME Transactions on Journal of Solar Energy Engineering,2006,(04):516-531.
  • 2Guerri O,Sakout A,Hamdouni A. Numerical simulation of the fluid flow around a roof mounted wind turbine[J].Journal of Wind Engineering,2010,(05):501-515.
  • 3Alaydi J Y. A survey on the assessment of wind energy potential in Gaza Strip[J].Journal of Wind Engineering,2010,(05):531-541.
  • 4Zhao P,Wang J F,Xia J R,Dai Y P Sheng Y X Yue J. Performance evaluation and accuracy enhancement of a day-ahead wind power forecasting system in China[J].An International Journal of Renewable Energy,2012.234-241.
  • 5Sheridan B,Baker S D,Pearre N S,Firestone J,Kempton W. Calculating the offshore wind power resource:Robust assessment methods applied to the U.S.Atlantic Coast[J].An International Journal of Renewable Energy,2012.224-233.
  • 6Ren D D. Effects of global warming on wind energy availability[J].Journal of Renewable and Sustainable Energy,2010,(05):1-5.
  • 7A1-Badi A H. Wind power potential in Oman[J].International Journal of Sustainable Energy,2011,(02):110-118.

引证文献3