出处
《高电压技术》
EI
CAS
CSCD
北大核心
2012年第8期1856-1862,共7页
High Voltage Engineering
基金
supported by National High-tech Research and Development Program of China(863 Program)(2009AA04Z416)
National Science Foundation of China(51021005)
Scientific Innovation of Colleges and Universities(Project v-200704)
关键词
局部放电
射频信号
放电量
高电压技术
converter transformer
insulation
oil-impregnated paper
AC-DC combined voltages
partial discharge
statistical phase-resolved distribution
作者简介
LI Jian(M'05)received his M.S.and Ph.D.degrees in electrical engineering in 1997 and 2001,respectively from Chongqing Uni versity,Chongqing,China.He is currently a professor and the head of High Voltage and Insulation Technology Department at Chongqing University.His major research interests include online detection of insulation condition in electrical devices,partial dischar ges,and insulation fault diagnosis for high voltage equipment,en vironment friendly insulating liquid,anti-icing coating of insulator and transmission line,and polyethylene/organie-montmorillonite nano-composites.He is an author and coauthor of more than 50 journal papers and 50 papers published in proceedings of interna-tional conferences.E-mail:lijian@cqu.edu.cn;JIANG Tianyan received his Bachelor degree in electrical engineering in 2008,from Chongqing University,China.He is currently a Ph.D.candidate at Chongqing University.His major research interests include partial discharges,online detection of insulation con-dition in electrical devices and insulation fault diagnosis of electrical equipment.He is a win-ner of the award of academic nova for doctoral student from the ministry of education of China.E-mail:jiangtianyan@cqu.edu.cn;HE Zhiman received his Bachelor degree in electrical engineering in 2008,from Southwest Jiaotong University,Chengdu,China.He is currently a Ph.D.candidate in the electrical engineering college of Chongqing University,Chongqing,China,His major research inter-ests include condition assessment of trans-former,online detection of insulation condi-tion in electrical devices and insulation fault di-agnosis for high voltage equipment.E-mail:hezhiman@cqu.edu.cn;CHENG Changkui received his Master de-gree in electrical engineering in 2009,from Chongqing University,Chongqing,China.He is currently a Ph.D.candidate at Chongqing University.His major research in-terests inelude partial discharges,online de-tection and insulation fault diagnosis of elec-trical equipment.E-mail:chengchen3@163.com;BAO Lianwei received his Bachelor degree in electrical engineering in 2010,from Southwest Jiaotong University,Chengdu,China.He is currently a Master candidate in the elect rica-lengineering college of Chongqing University,Chongqing.China.His major research inter-ests include transformer condition assessment and insulation fault diagnosis for high voltage equipment.E-mail:baolianwei@yahoo.com.cn.