摘要 报道了一种新的测量大尺度冷原子团温度的方法。这种方法利用反亥姆霍兹线圈产生四极磁场,探测光沿着竖直方向逐点测量冷原子团的分布情况,获得冷原子团在不同自由下落时间下的密度分布曲线,进而拟合出冷原子团的温度值。通过实验,利用这种方法测量了积分球中冷原子团的温度,为73±12μK,并与飞行时间(TOF)方法的测量结果进行了比较。 A new approach to measure the temperature of large-scaled cold atomic cloud is reported. In this approach, a pair of anti-Helmholtz coils is used to generate a quadrupole magnetic field, the spatial distributions of cold atoms in different moments are measured by applying a vertical probe beam which can detect the density of cold atomic cloud point by point, and then the temperature of cold atoms is fitted from the experimental results. The temperature of cold atoms in integrating sphere is demonstrated to be 73± 12 μK by using this approach. The result is also compared with time-of-flight (TOF) method.
出处 《光学学报》 EI CAS CSCD 北大核心 2012年第8期37-41,共5页 Acta Optica Sinica
基金 国家自然科学基金(10874193 11074262 11034008)资助课题
关键词 原子与分子物理学 激光冷却 飞行时间法 冷原子分布 冷原子温度 冷原子钟 atomic and molecular physics laser cooling time-of-flight spatial distribution of cold atoms temperature of cold atoms cold atom clock
作者简介 王旭成(1983-),男,博士研究生,主要从事激光冷却与小型化冷原子钟等方面的研究。E-mail:wangxc@siom.ac.cn 导师简介:刘亮(1963-),男,研究员,主要从事冷原子物理、原子钟和原子干涉仪等方面的研究。E—mail:liang.1iu@siom.ac.cn