期刊文献+

圆锥角膜患者配戴硬性透氧性角膜接触镜后波前像差的改变 被引量:2

Changes of wavefront aberrations in keratoconus corrected with rigid gas permeable contact lens
原文传递
导出
摘要 目的研究圆锥角膜患者配戴硬性透氧性角膜接触镜(RGPCL)后波前像差及视觉质量的改变。方法前瞻性病例对照研究。收集在山西省眼科医院就诊的圆锥角膜患者25例(43眼),选配合适的RGPCL配戴2周后,分别于配戴前及配戴后测定其矫正视力,采用iTrace波前像差仪进行戴镜前后的全眼波前像差测量,并测量戴镜前后高阶、低阶像差及高阶像差中的球差、彗差及三叶草样散光。采用配对样本t检验对数据进行统计学分析。结果配戴RGPCL前后,配戴前眼球总像差为(9.12±4.20)μm,配戴后为(1.67±0.92)μm,差异有统计学意义(t=9.062,P〈0.01)。低阶像差在配戴前为(8.88±3.90)μm,配戴后为(1.37±0.75)μm,差异有统计学意义(t=9.507,P〈0.01);高阶像差在配戴前为(1.90±0.14)μm,配戴后为(0.79±0.21)μm,差异有统计学意义(t=2.473,P〈0.05);彗差在配戴前为(0.99±0.15)μm,配戴后为(0.30±0.18)μm,差异有统计学意义(t=2.364,P〈0.05);三叶草样散光在配戴RGPCL前为(0.92±0.19)μm,配戴后为(022±0.14)μm,差异有统计学意义(t=2.757,P〈0.05);球差在配戴RGPCL前为(0.54±0.25)μm,配戴后为(0.32±0.27)μm,差异无统计学意义(t=1.239,P〉0.05)。结论RGPCL为圆锥角膜患者提供了良好的矫正视力,配戴RGPCL后波前像差明显降低,视觉质量明显改善。 Objective To investigate the changes of wavefront aberrations in keratoconus corrected with rigid gas permeable contact lens (RGPCL). Methods It was a prospective case-control study. Twenty-five patients (43 eyes) confirmed by corneal topography as keratoconus were corrected with RGPCL. Their corrected visual acuity (VA) and wavefront aberrations were detected by iTrace dynamic laserefraetion before and after wearing RGPCL for 2 weeks. Lower-order abberations LOAs, higher-order abberation HOAs, coma, spherical and trefoil were measured. The results measured were compared using paired samples t test. Results There were statistic differences in total ocular wavefront aberrations, LOAs, HOAs, coma and trefoil. Total ocular wavefront aberrations were reduced from 9.12±4.20 μm to 1.67±0.92 μm after wearing RGPCL (t=9.062, P〈0.01); LOAs were reduced from 8.88±3.90 μm to 1.37±0.75 μm after wearing RGPCL (t=9.507, P〈0.01); HOAs were reduced from 1.90±0.14 μm to 0.79±0.21 μm after wearing RGPCL (t=2.473, P〈0.05); coma were reduced from 0.99±0.15 μm to 0.30±0.18 μm after wearing RGPCL (t=2.364, P〈0.05); trefoil were reduced from 0.92±0.19 μm to 0.22±0.14 μm after wearing RGPCL (t=2.757, P〈0.05). There were no statistics differences in spherical abberation. Spherical abberation were reduced from 0.54±0.25 μm to 0.32±0.27 μm after wearing RGPCL (t=1.239, P〉0.05). Conclusion Keratoconus patients with RGPCL can reach satisfying corrected visual acuity and visual quantity. Total ocular wavefront aberrations were significant reduced after wearing RGPCL.
机构地区 山西省眼科医院
出处 《中华眼视光学与视觉科学杂志》 CAS 2012年第7期422-424,共3页 Chinese Journal Of Optometry Ophthalmology And Visual Science
关键词 波前像差 接触镜 硬性透气性 圆锥角膜 Wavefront aberrations Contact lenses,rigid gas pernleable Keratoconus
作者简介 通信作者:张立华,Email:wolfscat@126.com
  • 相关文献

参考文献13

  • 1Applegate RA, Howland HC. Refractive surgery, optical aberrations, and visual performance. J Refract Surg,1997,13: 295-299.
  • 2Roberts~ C: Future challenges to aberration-free ablative procedures J Refract Surg, 2000,16 : S623-639.
  • 3Almahmoud T Munger R, Jackson WB. Advanced corneal surface abiation efficacy in myopia: changes in higher order aberrations. Can J Ophthalmol,2011,46:175-181.
  • 4Cheng X, Bradley A, Ravikumar S, et al. Visual impact of Zernike and Seidel forms of monochromatic aberrations. Optom Vis Scii2010,87:300-312.
  • 5Marcos S, Cano D, Barbero S. Increase in corneal asphericity after standard laser in situ keratomileusis for myopia is not inherent to the Munnerlyn algorithm. J Refract Surg,2003,19: S592-596.
  • 6张立华,贾丁,王文平.圆锥角膜配戴硬性透气性角膜接触镜后角膜表面形态的改变[J].中国实用眼科杂志,2011,29(9):906-908. 被引量:7
  • 7Fink BA, Mitchell GL, Raasch TW, et al. Enhancing RGP contact lens performance: comparing back surface options. Optometry, 2002,73 : 605-613.
  • 8阎静.Rose K RGP对圆锥角膜矫正视力影响的初步观察[J].国际眼科杂志,2009,9(9):1687-1689. 被引量:3
  • 9钟兴武,龚向明,杨晓,戴祖优,魏玲,李树兴.Rose K硬透气性接触镜矫治圆锥角膜的临床观察[J].中国实用眼科杂志,2005,23(2):182-184. 被引量:26
  • 10Pantanelli S, MacRae S, Jeong TM, et al. Characterizing the aberration in eyes with keratoconus or penetrating keratoplasty using a high-dynamic range wavefront sensor. Ophthalmology, 2007,114 : 2013-2021.

二级参考文献24

  • 1钟兴武,龚向明,杨晓,戴祖优,魏玲,李树兴.Rose K硬透气性接触镜矫治圆锥角膜的临床观察[J].中国实用眼科杂志,2005,23(2):182-184. 被引量:26
  • 2王丽强,刘莉,黄一飞.硬性透气性隐形眼镜(RGP)矫正圆锥角膜的疗效分析(英文)[J].国际眼科杂志,2006,6(5):1002-1004. 被引量:7
  • 3沈政伟,周和政,吴金桃,尹禾,李丽.正常眼角膜Q值检测分析[J].国际眼科杂志,2006,6(6):1356-1357. 被引量:13
  • 4O'Donnell C,Maldonado-Codina C.A hyper-Dk piggyback contact lens system for keratoconus.Eye Contact Len2004;30(1):44-48.
  • 5Edrington TB,Gundel RE,Libassi DP,et al.Variables affecting rigid contact lens comfort in the collaborative longitudinal evaluation of keratoconus (CLEK) study.Optom Vis Sci2004;81(3):182-188.
  • 6Caroline PJ,Norman CW,Andre MP.The latest lens design for keratoconus.Contact Lens Spectrum1997;14:36-41.
  • 7Rabinowitz YS.Keratoconus.Surv Ophthalmol1998;42:297-319.
  • 8Betts AM,Mitchell GL,Zadnik K.Visual performance and comfort with the Rose K lens for keratoconus.Optom Vis Sci2002;79(8):493-501.
  • 9Leung KK.RGP fitting philosophies for keratoconus.Clin Exp Optom 1999;82(6):230-235.
  • 10Pinero DP,Alio JL. Intracorneal ring segments in ectatic corneal disease-a review [J]. Clin Experiment Ophthalmol,2010,38 (2) : 154-67.

共引文献43

同被引文献16

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部