本文通过删去灰化步骤 ,缩短干燥时间 ,在无基体改进剂的条件下 ,提出了快速测定水中痕量铜、铅和镉的方法。方法简单、快速。
The Determination of trace copper and Lead and Cadmium in drinking water by rapid GFAAS has been described in this paper,Which is based on eliminating ashing step,shortening drging time and without chemical Matrix modifier.The fast speed and simplicity makes it possible for routine analysis.