期刊文献+

甲状腺结节超声引导下穿刺活检的临床价值 被引量:9

Clinic value of ultrasound-guided needle biopsy for the diagnosis of thyroid nodule lesions
在线阅读 下载PDF
导出
摘要 目的探讨超声引导下粗针(18G)穿刺活检(ultrasound-guided coarse needle biopsy,US-CNB)对甲状腺结节的临床诊断价值。方法对2010年10月-2011年5月在解放军总医院就诊的150例157个甲状腺结节进行US-CNB,以手术切除病理结果作为金标准,将US-CNB的病理结果与手术病理结果进行对照。US-CNB的病理学诊断分为良性、恶性、诊断不明确三类。结果 157个结节,最终诊断为恶性结节139个,良性结节18个。穿刺活检病理学诊断为恶性131个(83.45%),良性17个(10.83%),9个(5.73%)诊断不明确;US-CNB病理学诊断的灵敏度96.27%,特异度85.71%,准确度95.27%。1例(0.63%)发生穿刺后出血。取材标本的最大径≥0.4cm时可以提高诊断准确率。结论超声引导下经皮甲状腺穿刺简便、安全,是非手术条件下穿刺病检的首要方法。 Objective To study the clinical diagnostic value of ultrasound-guided coarse needle(18G) biopsy(US-CNB) for diagnosis of thyroid nodule lesions. Methods One hundred and fifty patients(157 thyroid nodules) who underwent US-CNB and surgery in Chinese PLA General Hospital from October 2010 to May 2011 were included in this study. The findings in US-CNB and surgery were compared. The US-CNB demonstrated that thyroid nodule lesions could be classified as benign, malignant or uncertain. Results Of the 157 thyroid nodule lesions, 139 and 18 were diagnosed as malignant and benign respectively, while 131(81.45%), 17(10.83%) and 9(5.73%) were diagnosed as malignant, benign and uncertain respectively by US-CNB, with a sensitivity of 96.27%, a specificity of 85.71% and an accuracy of 95.27%. Bleeding occurred in 1 patient(0.63%) after puncture. The diagnosis rate was increased when the thyroid nodule sample with its maximum diameter ≥ 0.4cm was used. Conclusion US-CNB is a safe and simple procedure for the puncture of thyroid nodule lesions when surgical sampling is impossible.
出处 《军医进修学院学报》 CAS 2012年第5期473-475,共3页 Academic Journal of Pla Postgraduate Medical School
关键词 超声引导 甲状腺结节 穿刺活检 ultrasound-guided thyroid nodules puncture biopsy
作者简介 魏小丽,女,硕士。研究方向:超声。Email:wmll98641@163.com 于晓玲,女,教授,主任医师。Emaihdyuxl301yahoo.con.cn;郝晓云,女,教授,主任医师。Email:haoxiaoyun1915@163.com
  • 相关文献

参考文献3

二级参考文献15

  • 1赵光明,张雪鹏,马琳,李瑞伟,朱红成,张文杰.彩色多普勒引导下甲状腺结节粗针穿刺活检的诊断意义[J].实用癌症杂志,2004,19(4):420-421. 被引量:20
  • 2吕国荣,吴春林,王静意,吕肖鑫,张武,贾建文.手动与自动肿瘤活检针道细胞种植实验研究[J].中华超声影像学杂志,1994,3(2):90-92. 被引量:11
  • 3Screaton N J, Berman L H, Grant J W. US-guided core-needle biopsy of the thyroid gland[J]. Radiology,2003,226(3) :827-832.
  • 4Fornage B D. Guided fine-needle aspiration biopsy of nonpalpable breast lesions:calculation of accuracy values[J]. Radiology, 1990,177(3):884-885.
  • 5Christopher D.M.Fletcher.周庚寅,刘洪琪,张庆慧,译.肿瘤病理组织诊断[M].济南:山东科学技术出版社,2001:599-648.
  • 6Quinn S F, Nelson H A, Demlow T A. Thyroid biopsies: fine-needle aspiration biopsy versus spring-activated core biopsy needle in 102 patients[J]. J Vasc Interv Radiol, 1994,5 (4) : 619-623.
  • 7Taki S, Kakuda K, Kakuma K, et al. Thyroid nodules: evaluation with US guided core biopsy with an automated biopsy gun [J]. Radiology, 1997,202(3) : 874-877.
  • 8Lundstedt C, Stridbeck H, Andersson R,et al. Tumor seeding occurring after fine-needle biopsy of abdominal malignancies[J]. Acta Radiol,1991,32(6):518-520.
  • 9Fornari F, Civardi G, Cavanna L, et al. Complications of ultrasonically guided fine-needle abdominal biopsy. Results of a muhicenter Italian study and review of the literature. The Cooperative Italian Study Group[J]. Scand J Gastroenterol,1989,24(8) :949-955.
  • 10Eriksson O, Hagmar B, Ryd W. Effects of fine-needle aspiration and other biopsy procedures on tumor dissemination in mice[J]. Cancer, 1984,54(1):73-78.

共引文献124

同被引文献76

引证文献9

二级引证文献65

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部