摘要 结合某300MW机组5号低压加热器出口的凝结水参数及其管道尺寸,设计出一种便携式一体化孔板流量测量装置,在该装置前、后分别自带长度为3D、2D的直管段,由带颈对焊法兰与管道连接,以减少法兰对孔板前后流场的影响。对该流量测量装置进行标定的结果表明,其测量最大误差为0.85%左右,满足汽轮机热力性能试验对流体流量测量精度的要求。 Combined with parameters of condensate at outlet of the low-pressure heater no.5 of one 300MW unit as well as the size of pipelines,a portable integrated perforated-plate type flow-rate meter has been designed.Before and after the said meter,straight pipe-sections,with length of 3D and 2D respectively,are connected to pipelines by using butt-welded flange,so as to reduce the influence of flange upon the flow field of fluid before and after the peforated plate.The result of calibration of said flow-rate meter shows that the maximum error in measurement is about 0.85%,satisfying the requirement in measurement precission of fluid flowrate in thermodynamic performance test of steam turbines.
作者 李勇 王加勇
出处 《热力发电》 CAS 北大核心 2012年第3期26-28,36,共4页 Thermal Power Generation
基金 吉林省科技发展计划项目(20080523)
关键词 300MW机组 汽轮机 凝结水 流量 便携式流量计 测量精度 300 MW unit steam turbine condensate portable flow-rate meter flow rate measurement precission
作者简介 李勇(1964-),男,辽宁本溪人,博士,教授,从事汽轮机运行性能检测与优化运行的教学与研究。E—mail:sdlcsxdzwjy@163.com
  • 相关文献

参考文献8

二级参考文献7

  • 1王松岭,安连锁,张虎林.一种无节流监测汽水管道流量的简便方法[J].流体工程,1993,21(2):38-42. 被引量:1
  • 2郑洽余 鲁钟琪.流体力学[M].北京:机械工业出版社,1980.253-256.
  • 3潘锦珊.气体动力学基础(修订版)[M].北京:国防工业出版社,1988.
  • 4王幼良.流体输送管路计算方法的改进[J].流体工程,1986,(2):21-24.
  • 5山东工学院,东北电力学院.工程流体力学[M].北京:水利电力出版社,1979.103-108
  • 6JJG 640-1994.差压式流量计检定规程[S],1994.
  • 7孙延祚.“V”型内锥式流量计[J].天然气工业,2004,24(3):105-110. 被引量:55