摘要
通过宏观形貌和显微组织观察、化学成分分析和断口分析等方法,对两根套管在静水压试验过程中发生爆裂的原因进行了分析。结果表明:套管发生纵向爆裂的原因是热处理工艺参数选择不合理,导致管体内表面存在淬火裂纹,致使套管在静水压试验中因不能承受压力过载而发生爆裂。
The cracking reason of two casings during hydrostatic test was analyzed by means of macrograph and microstructure observation,chemical composition analysist and fracture analysis,et al.The results show that the reason of the casings longitudinal cracking was improper heat treatment process parameters,which resulted in the quenching cracks appeared on the inner surface of casings,and the quenching cracks led to the casings could not endure pressure overload during hydrostatic test.
出处
《机械工程材料》
CAS
CSCD
北大核心
2012年第3期97-100,共4页
Materials For Mechanical Engineering
关键词
静水压试验
爆裂
淬火裂纹
套管
hydrostatic test
cracking
quenching crack
casing
作者简介
张春婉(1980-),女,陕西户县人,工程师,硕士。