期刊文献+

基于增强的谱分析和奇异值分解的T波交替检测 被引量:2

T-wave alternans detection based on enhanced spectral method and singular value decomposition
在线阅读 下载PDF
导出
摘要 针对传统谱分析方法在T波交替(TWA)检测中对噪声敏感的缺点,提出将增强的谱分析方法和奇异值分解方法结合起来的TWA检测方法.该方法利用奇异值分解得到去除了噪声干扰的心电信号,克服了传统谱分析方法只能检测平稳信号且需要增大心率的缺点,强调交替水平的重要性,即增强TWA功率谱上0.5cpb处的幅值,实现对TWA的有效分析.研究结果表明:该方法对T波交替数据库中30个人工合成并含有TWA的数据的检出准确率达93.33%,高于传统谱分析方法的TWA阳性检测率,能够提高交替比率.TWA检测率明显高于phys-ionet网站中2008年挑战(TWA检测和定量分析)得分第一的算法实验结果(66.67%),说明该方法具有更强的TWA识别能力. A method for the detection of T-wave alternans(TWA) was proposed through the fusion of enhanced spectral analysis and singular value decomposition in order to overcome the shortcoming of the traditional spectral analysis being sensitive to noise.Electrocardiosignal was effectively denoised by using singular value decomposition.The shortcomings of traditional spectral method including limitation to stationary signals and requirement of increased heart rates were overcome.The importance of alternans level was emphasized through increasing the amplitude of 0.5 cpb place on TWA spectrum in order to realize the effective analysis of TWA.Results showed that the accuracy of the algorithm was 93.33% for 30 synthetic electrocardiograms containing TWA in T-wave alternans database with increased alternans ratio and accuracy compared with traditional spectral analysis,which was obviously better than the result(66.67%) from the algorithm scored first in physionet 2008 challenge(TWA detection and quantitative analysis).The method is more effective for identifying TWA.
出处 《浙江大学学报(工学版)》 EI CAS CSCD 北大核心 2012年第1期177-181,共5页 Journal of Zhejiang University:Engineering Science
基金 国家自然科学基金资助项目(60801019) 教育部高校博士点新教师基金资助项目(200805331085)
关键词 T波交替(TWA) 奇异值分解(SVD) 谱分析 心脏性猝死 T-wave alternans(TWA) singular value decomposition(SVD) spectral analysis sudden cardiac death
作者简介 王娟(1983-),女,硕士生,从事医学信号处理研究.E—mail:w.juan_2009@163.com 通信联系人:刘正春,男。教授.E-mail:liuzhengchunseu@126.com
  • 相关文献

参考文献16

  • 1MOODY G B. The PhysioNet/computers in cardiology challenge 2008: T-wave alternans [C]// Computing in Cardiology. Bologna: IEEE , 2008:505 - 508.
  • 2HAGHJOO M, ARYA A, SADR-AMELI M A. Microvolt T-wave ahernans: a review of techniques, interpretation, utility, clinical studies, and future perspectives [J]. International Journal of Cardiology, 2006, 109(3) : 293 - 306.
  • 3BEATA S, AGATA M L, JACEK K. Current developments in microvolt T-wave alternans [J]. Indian Pacing and Elcctrophysiology Journal, 2006, 6(4) : 214 - 225.
  • 4MORENO-MARTINEZ E. Enhanced spectral method for T-wave alternans analysis [C]// 2007 IEEE International Symposium on Intelligent Signal Processing. New York: IEEE, 2007:651-656.
  • 5MATINEZ J P, OLMOS S. Methodological principles of T wave alternans analysis: a unified framework [J]. IEEE Transactions on Biomedical Engineering, 2005, 52(4) : 599 - 611.
  • 6KHAUSTOV A, NEMATI S, CLIFFORD G D. An open-source standard T-wave alternans detector for benchmarking [C]// Computing in Cardiology. Bologna: IEEE, 2008: 509-512.
  • 7LI C, ZHENG C, TAI C. Detection of ECG characteristic points using wavelet transforms [J]. IEEE Transactions on Biomedical Engineering, 1995, 42(1): 21 -28.
  • 8MARTJNEZ J P, ALMEIDA R, OLMOS S. A waveletbased ECG delineator: evaluation on standard databases[J]. IEEE Transactions on Biomedical Engineering, 2004, 51(4): 570-581.
  • 9SHEN T W, TSAO Y T. An improved spectral method of detecting and quantifying T-wave alternans for SCD risk evaluation [C]//Computing in Cardiology. Bologna : IEEE, 2008:609-612.
  • 10ADAM D R, SMITH J M, AKSELROD S, et al. Fluctuations in T-wave morphology and susceptibility to ventricular fibrillation [J]. Journal of Eiectrocardiology, 1984, 17(3).. 209-218.

二级参考文献16

共引文献32

同被引文献22

  • 1张士峰.混合正态分布参数极大似然估计的EM算法[J].飞行器测控学报,2004,23(4):47-52. 被引量:19
  • 2赵捷,华玫.基于T波最大值的T波电交替分析法[J].生物医学工程学杂志,2005,22(5):951-955. 被引量:10
  • 3FURLANELLO F, GALANTI G, MANETTI P. Micro- volt T-wave alternans as predictor of electrophysiological testing results in professional competitive athletes [ J ]. Ann Noninvasive Electrocardiol, 2004, 9 ( 3 ) : 201 - 206.
  • 4VERRIER R L, IKEDA T. Ambulatory ECG-based T- wave alternans monitoring for risk assessment and guid- ing medical therapy: Mechanisms and clinical applica- tions [ J ]. Progress in Cardiovascular Diseases, 2013, 56(2) :172 - 183.
  • 5ARMOUNDAS A A, MELA T, MERCHANT F M. On the estimation of T-wave ahernans using the spectral fast fourier transform method [ J]. Heart Rhythm, 2012, 9 (3) : 449 -456.
  • 6BUR ATrlNI L, BINI S, BURATrlNI R. Correlation method versus enhanced modified moving average method for automatic detection of T-wave alternans [J], Computer Methods and Programs in Biomedicine, 2010, 98( 1 ) : 94- 102.
  • 7STRUMILLO P, RUTA J. Poincar6 mapping for detecting abnormal dynamics of cardiac repolarization [ J ]. IEEE Eng Med Biol Mag, 2002, 21 (1) : 62 -65.
  • 8CUESTA F,MICO T P, ABOY M. Enhanced modified moving average analysis of T- wave alternans using a curve matching method : a simulation study [ J ]. Medi- cal & Biological Engineering & Computing, 2009 , 47 (3) : 323 - 331.
  • 9MARTiNEZ J P, OLMOS S. Methodological principles of T wave ahernans analysis:a unified framework [ J ]. IEEE Transactions on Bio-medical Engineering,2005,52 (4) :599-613.
  • 10NARAYAN S M, BOTI'ERON G W, SMITH J M. T- wave alternans spectral magnitude is sensitive to ECG beat alignment strategy[ J]. IEEE Trans on Computer in Cardiology, 1997, 24 (3) : 593 - 596.

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部