摘要 大型建材家居类商场存在建筑面积大,人员密度小,所需疏散宽度小等特点,这类商场往往存在两方面问题:①为满足2层以上楼层对疏散距离的需要,致使首层部分楼梯的疏散出口不能直通室外以及疏散距离过长;②为满足疏散出口直通室外,楼梯沿建筑外墙布置,致使某些楼层的一些区域的疏散距离过长。对比了国家规范和地方规范对人员密度规定的差异,提出了系统的解决方案:①对于设有中庭的商场,应控制人员数量,强化中庭的消防安全设计将其设置为"准安全区",严格控制中庭以及消防通道的可燃物量,保证疏散通道顺畅;②对于楼梯沿建筑外墙布置的商场,应控制人员数量,设置借用出口,发生火灾的防火分区的人员通过相邻防火分区进行疏散。采用数值模拟方法验证了解决方案的合理性。 The large-scale malls for building materials and furnitures genearlly involve large construction area, small personnel density and small evacuation width, leading to some safety problems. For example, for the need of evacuation distance in floors above the second layer, the evacuation exits of some stairs in the first floor cannot be designed to be directly in the face of the outside, and usually the first floor involves too long evacuation distance. In other cases, in order to make the evacuation exits of the stairs directly face the outside, the stairs are sometimes arranged along the exterior walls, causing excessive evacuation dis- tance in some areas. This paper compares the different provisions of personnel density between national standards and local reg- ulations, and then proposes systematic solutions. Firstly, for the malls with atriums, we should control the personnel number, strengthen the fire safety design of atrium by designing it as a quasi-safety zone. The amount of combustible in the atrium and fire channel should also be controlled strictly. In this way, it is easily to make the evacuation routes be unobstructed. Secondly, for the stairs along the exterior walls, we should control the personnel number and design the borrowed exits between the neighboring fire districts. By this means the people in the fire district can be evacuated to the neighboring fire districts. The solutions are also verified by numerical simulations.
出处 《火灾科学》 CAS CSCD 2011年第4期206-215,共10页 Fire Safety Science
关键词 大型建材家居商场 建筑面积大 人员密度小 准安全区 借用出口 Large-scale malls for building materials and furnitures Large building area Personnel density Quasi-safety Zone
作者简介 赵军(1974-),内蒙古消防总队防火监督处处长,工程师,专业为消防工程,研究方向为建筑防火与人员疏散安全研究。
  • 相关文献

参考文献5

二级参考文献25

  • 1吴凤,邓军,沈奕辉.浅谈大型地下商场安全岛的设置[J].中国安全科学学报,2004,14(8):71-74. 被引量:7
  • 2王平,方正,袁建平,汪尚朋.高层建筑人员疏散模型及其验证[J].火灾科学,2005,14(2):75-79. 被引量:23
  • 3王蔚,张和平,徐亮,杨昀.大中庭建筑的性能化防火设计初探[J].建筑学报,2006(7):48-49. 被引量:17
  • 4Kevin M,Bryan K.Fire Dynamics Simulator (Version 5) User's Guide[M].U.S.Government printing office.Washington:2007.
  • 5The SFPE Handbook of Fire Protection Engineering(Third Edition)[M].by Philip J.DiNenno(ed.).Society of Fire Protection Engineers and National Fire Protection,2008.
  • 6《建筑设计防火规范》 (GB16-87)[M],中华人民共和国公安部,中华人民共和国建设部,2001.
  • 7NFPA92B,Guide for Smoke Management Systems in Mall,Atria,and Large Areas 2000Edition[M].USA:National Fire Protection Association,2000.
  • 8《民用建筑防排烟技术规程》 (DGJ 08-88-2000)[M].上海市消防局,2000.
  • 9《高层民用建筑设计防火规范》 (GB50045-95)[M],中华人民共和国公安部,2001.
  • 10GB50157-2003.地铁设计规范[S].[S].,..