摘要
采用三元微电解—Fenton试剂氧化法处理COD为60~90 mg/L的石化废水。三元微电解工艺最优条件为:m(铝屑)∶m(铁屑)∶m(活性碳)=1∶2∶2,废水初始pH 4~5,微电解时间45 min。Fenton试剂氧化工艺最优条件为:H2O2加入量0.6 mL/L,废水pH 4,氧化时间30 min。在此条件下,石化废水最终出水COD小于30 mg/L,总COD去除率达到71.0%以上。
Petrochemical wastewater with 60 -90 mg/L of COD was treated by microelectrolysis-Fenton reagent oxidation process. The optimum conditions for ternary ternary microelectrolysis are as follows: m (A1) : m (Fe) : m (C) = 1 : 2 : 2, initial wastewater pH 4 -5, microelectrolysis time 45 min. The optimum conditions for Fenton reagent oxidation are as follows: H2O2 dosage 0.6 mL/L, wastewater pH 4, oxidation time 30 rain. Under these conditions, COD of the final effluent is less than 30 mg/L, and the total COD removal rate is above 71.0%.
出处
《化工环保》
CAS
CSCD
北大核心
2011年第6期519-523,共5页
Environmental Protection of Chemical Industry
基金
中国石化科技开发资助项目(G1715-2010-ZS0002)
关键词
三元微电解
FENTON试剂氧化
石化废水
废水处理
ternary micro-electrolysis
Fenton reagent oxidation
petrochemical wastewater
wastewater treatment
作者简介
曹雨平(1962-),男,江苏省金坛市人,硕士,教授,主要研究方向为工业节水与污水回用。电话0514—87433001,电邮ypcao@126.com。