期刊文献+

气相色谱质谱-内标法检测油漆中苯系物 被引量:27

Determination of Benzene Series Compounds in Oil Paints by Internal Standard Method Using GC/MS
在线阅读 下载PDF
导出
摘要 以氯苯为内标物,采用气相色谱-质谱联用仪对油漆中苯系物的检测技术进行了研究,考察了主要苯系物的线性、回收率和精密度情况,开发出一种同时检测油漆中六种苯系物的高灵敏度方法。对样品的色谱分离条件、提取溶剂、定量方法及内标物选择等进行了优化,实现了一次进样同时定性定量检测油漆中6种苯系物。六种苯系物在1.0~500.0μg/mL范围内线性良好,各种苯系物的标准工作曲线线性相关系数0.995 4~0.999 8;在100.0~500.0μg/mL浓度范围内,加标回收率在85.01%~107.44%之间,精密度在2.58%~12.43%之间;5种苯系物组分中苯、甲苯、乙苯、间(对)二甲苯、邻二甲苯的最小检测浓度(按三倍信噪比)分别为0.01、0.002、0.05、0.05、0.05μg/mL。该方法灵敏度较高,所得数据准确,是一种检测油漆等化工品中苯及同系物含量的有效方法。 A high sensitivity method for simultaneously analyzing 6 benzene series compounds contained in oil paints by GC/MS with chlorobenzene as internal standard was proposed.Liner,recovery and RSD of benzene series compounds were studied while chromatographic separation condition,extraction solvents,quantitative method and internal standard selection were optimized to achieve a best qualitative and quantitative detection condition.Results illuminated that linear correlation coefficients of benzene,toluene,ethylbenzene and dimethylbenzenes were in the range of 0.995 4~0.999 8,with good linear relativity.Recoveries were 85.01%~107.44% within the concentration range of 100.0~500.0 μg/mL,as well as RSD were 2.58%~12.43%.The minimum detection limit based on signal-to-noise ratio(S/N) were 0.002~0.05 μg/mL,which exhibited a high sensitivity and provided accurate data as an effective method to detect benzene series compounds contained in oil paints or other chemicals.
出处 《环境科学与技术》 CAS CSCD 北大核心 2011年第11期135-138,共4页 Environmental Science & Technology
基金 环境化学与生态毒理学国家重点实验室开放基金(KF2009-13)
关键词 气相色谱-质谱 苯系物 油漆 内标法 氯苯 GC-MS; benzene series compounds; oil paint; internal standard method; chlorobenzene
作者简介 刘明仁(1985-),男,硕士研究生,研究方向为主要从事环境有机污染物检测研究,(手机)15965530235(电子信箱)lmrlOOO@tom.com 通讯作者,(电话)0531-89736032(电子信箱)chm_zhangzl@ujn.edu.cn。
  • 相关文献

参考文献13

二级参考文献82

共引文献159

同被引文献247

引证文献27

二级引证文献99

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部