期刊文献+

64层螺旋CT血管造影在主动脉夹层动脉瘤中的应用 被引量:7

Diagnostic Value of 64-Detector Spiral CT Angiography for Dissecting Aneurysm of Aorta
在线阅读 下载PDF
导出
摘要 目的:评价64层螺旋CT血管造影在主动脉夹层动脉瘤中的应用价值。材料与方法:收集主动脉夹层动脉瘤CT血管造影41例,原始横断面图像结合MPR、MIP、VR进行图像分析。结果:原始横断面图像能明确主动脉夹层动脉瘤的诊断,能清晰显示真假腔41例(100%),分离移位的内膜片41例(100%)、内膜破口37例(90.2%)、主动脉分支受累21例(51.2%)、假腔内血栓形成27例(65.9%);MPR、MIP及VR能显示病变的空间情况,对原始横断面图像是很好的补充。对横断面图像较难显示小的内膜破裂口,MPR图像能清楚显示。MIP及VR可以立体、直观地显示主动脉夹层情况。结论:64层螺旋CT血管造影能明确诊断主动脉夹层动脉瘤,具有快速、准确、无创的特点,是诊断主动脉夹层动脉瘤的首选检查方法。 Objective:To evaluate clinical application value of 64-detector spiral CT angiography for dissecting aneurysm of aorta(ADA).Material and methods:CT angiography was performed in 41 cases with ADA,Original axial images combined with MPR,MIP and VR were analyzed.Results:The original axial images can diagnose ADA definitely and clearly show true lumen and false lumen(100%),intimal flap(100%),entry of intimal tear(90.2%),the involvement of branches of aortic(51.2%) and thrombosed false lumen(65.9%),The images of MPR,MIP and VR can show space conditions of aorta and is a very good supplement to the original axial images.The images of MPR can clearly show those entries of intimal tear that the axial images show difficultly,The images of MIP and VR can show the condition of ADA spatially and intuitively.Conclusion:64-detector spiral CT angiography can diagnose ADA definitely and are accurate,quick and non-trauma,so the examination may be as the first choice method in diagnosis of ADA.
出处 《CT理论与应用研究(中英文)》 2011年第3期391-396,共6页 Computerized Tomography Theory and Applications
关键词 主动脉 夹层动脉瘤 体层摄影术 X线计算机 血管造影 aorta dissecting aneurysm computed tomography X-ray computed angiography
作者简介 章绪辉(1975-),男,南方医科大学珠江医院放射科主治医师,在读博士,主要从事心胸影像诊断,Tel:13431027273,E-mail:xuhuizh1219@126.com;全显跃(1963--),男,南方医科大学珠江医院放射科主任医师、教授、博士研究生导师,广东省医学会放射医学分会委员,主要从事肝肿瘤的影像及病理对照研究及功能影像学研究,Tel:020-61643460,E-mail:quanxianyue@163.com。
  • 相关文献

参考文献8

  • 1Willoteaux S, Lions C, Gaxotte V, et al. Imaging of aortic dissection by helical computed tomographyEJ]. European Radiologg, 2004, 14(11): 1999-2008.
  • 2王虹,彭卫斌,赵亮,殷瑞根.夹层动脉瘤的多层螺旋CT成像技术[J].江苏大学学报(医学版),2006,16(3):222-225. 被引量:2
  • 3DebakeyME, Crawford ES, Mccollum CH, et al. Dissection and dissecting aneurysms of the aorta: twenty-year follow-up of five hundred twenty-seven patients treated surgically[J]. Surgery, 1982, 92(6): 1118-1134.
  • 4Thubrikar MJ, Agali P, Robicsek F. Wall stress as a possible mechanism for the development of transverse intimal tears in aortic dissections[J]. Journal of Medical Engineering & Technology, 1999, 23(4): 127-134.
  • 5包永军,伏辉,李阳.主动脉夹层动脉瘤的CT和MRI诊断[J].新疆医科大学学报,2008,31(7):877-879. 被引量:11
  • 6Rubin GD, Beaulieu CF, Armerding MD, et al. Aortic aneurysmal disease: Assessment of stent-graft treatment-CT versus conventional angiography[J]. Radiology, 2000, 215(1): 138-146.
  • 7贾崇富,王照谦,杨志强,卞晓明,孙喜霞,王海燕,郑鹏,谢丽伟.多层螺旋计算机断层摄影术在主动脉夹层腔内隔绝术后随访中的价值[J].中国循环杂志,2010,25(4):292-294. 被引量:11
  • 8Ota H, Takase K, Igarashi K, et al. MDCT compared with digital subtraction angiography for assessment of lower extremity arterial occlusive disease: importance of reviewing cross-sectional images[J]. AJR, 2004, 182(1): 201-209.

二级参考文献20

  • 1陈阿梅,韩萍,陈艳,梁波,雷子乔,田志梁.主动脉病变腔内隔绝术后多层螺旋CT血管造影的应用价值[J].中国医学科学院学报,2006,28(1):93-95. 被引量:10
  • 2林江,王建华,严福华,曾蒙苏,徐鹏举,周康荣.32接收通道并行采集全身MR血管成像技术的临床应用初探[J].中华放射学杂志,2006,40(4):426-430. 被引量:18
  • 3陈祖望,周康荣,陈福真,王述静,杨培强,沈继章,陈财忠,施伟斌.主动脉夹层几种磁共振影像的评价和比较[J].中华放射学杂志,1997,31(1):15-19. 被引量:24
  • 4Rossella F, Gabriellaj N, Luigi L, et al. Descending thoracic aortic diseases : stent-graft repair. Radiology,2003,229 ( 1 ) : 176-183.
  • 5Dake MD, Miller C, Semba CP, et al. Transluminal placement of endovascular sent-grafts for treatment of descending thoracic aortic aneurysms. N Engl J Med,1994,331 (26) :1729.
  • 6Pitton MB, Herber S, Schmiedt W, et al. Long-term follow-up after endovascular treatment of acute aortic emergencies. Cardiovazc Intervent Radiol,2008 ,31:23-35.
  • 7Tespili M, Banff C, Valseeehi O, et al. Endovaseular treatment of thoracic aortic disease: mid-term follow-up. Catheter Cardiovase Interv, 2007,70:595-601.
  • 8Isselbacher EM. Thoracic and abdominal aortic aneurysms. Circulation ,2005,111 :816-828.
  • 9White GH, May J, Waugh RC, et al. Type m and type IV endoleak : to-ward a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg, 1998,5 : 305-309.
  • 10Chuter TA, Faruqi RM, Sawhney R, et al. Endoleak after endovascular repair of abdominal aortic aneurysm. J Vasc Surg,2001,34 :98-105.

共引文献21

同被引文献44

  • 1江金带,李扬彬,谭理连,李树欣,梁彤杰,周少萍.多层螺旋CT血管造影在颈动脉病变诊断中的应用[J].中国CT和MRI杂志,2006,4(2):4-6. 被引量:33
  • 2Riesenman P J, Farber M A, Mendes R R,et al. Coverage of the left subclavian artery during thoracic endovascular aortic repair [J]. J Vasc Surg,2007,45( 1 ) :90 -4.
  • 3Fanelli F, Dake M D, Salvatori F M, et al. Management strategies for thoracic stent-graft repair of distal aortic arch lesions : is inten- tional subclavian artery occlusion a safe procedure? [ J]. Eur Ra- diol, 2009,19 (10) :2407 - 15.
  • 4Bortone A S, De Cillis E, D'Agostino D,et al. Endovascular treat- ment of thoracic aortic disease : four years of experience [ J ]. Circu- lation,2004,110( 11 ) : Ⅱ262 -7.
  • 5Armerding MD,Rubin GD,Beaulieu CF, et al.Aortic aneurismal disease:assessment of stent-graft treatment-CT versus conventional angiography[J].Radiology,2000,215 ( 1 ): 138-146.
  • 6Ota H,Takase K,Igarashi K,et al.MDCT compared with digital subtraction angiography for assessment of lower extremity arterial occlusive disease:importance of reviewing cross- sectional images[J].AJR Am J Roentgenol,2004,182(1):201-209.
  • 7Willoteaux S,Lions C,Gaxotte V, et al.Imaging of aortic dissection by helical computed tomography(CT)[J].Eur Radiol,2004,14( 11 ):1999-2008.
  • 8刘磊,庞闽厦,杨新国,宋殿行,周晓明,郭秀琴.颈脑动脉联合CTA与DSA诊断缺血性脑血管病动脉狭窄的对比研究[J].中国临床医学影像杂志,2009,20(5):351-353. 被引量:11
  • 9周新元.颈动脉超声和DSA对颈动脉狭窄诊断的比较[J].中国现代药物应用,2010,4(3):21-22. 被引量:8
  • 10石银龙,庞长珠,康桂荣,李梅,张廉良.16层螺旋CTA成像技术在主动脉夹层动脉瘤中的应用[J].中国医疗设备,2010,25(8):144-145. 被引量:11

引证文献7

二级引证文献64

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部