期刊文献+

化学沉淀法处理线路板厂含镍废水 被引量:29

REMOVING NICKEL FROM ELECTROPLATING WASTEWATER BY CHEMICAL PRECIPITATION
原文传递
导出
摘要 为使某线路板厂含镍废水达标排放,模拟该厂含镍废水处理工艺条件,采用硫化钠和硫酸亚铁相结合的化学沉淀法进行小试,通过正交实验确定最佳药剂投加量。结果表明:处理该含镍废水的最佳操作条件是pH=2,FeSO4.7H2 O投加量为1.29 g/L,Na2 S的投加量为0.52 g/L,LIME的投加量为1.12 g/L,PAM投加量为0.02 g/L。此时废水中的镍含量从20.5 mg/L降至0.022 mg/L,镍的去除率达99%以上。将最佳工艺条件应用于工程实践,镍的去除率从原有的95.1%提高到98.9%,废水中镍含量低于0.5 mg/L,达到GB 21900—2008《电镀污染物排放标准》中镍的排放标准。 The research aims to seek the optimum operating conditions of treating nickel wastewater from a printed circuit board plant by orthogonal test.The results show that the removal rate of nickel in the wastewater can be higher than 99% when pH value is at 2;concentration of FeSO4·7H2O is at 1.29g/L;concentration of Na2S is at 0.52 g/L;concentration of LIME is at 1.12 g/L,and concentration of PAM is at 0.02 g/L.When these optimum operating conditions are applied to actual project,the removal rate of nickel can also reach 98.9%,higher than the original 95.1%,and the content of nickel in effluent is lower than 0.5 mg/L.
出处 《环境工程》 CAS CSCD 北大核心 2011年第4期50-53,66,共5页 Environmental Engineering
基金 井冈山大学2009年自然科学基金项目(JZ09017) 井冈山大学2009年校级教学改革课题(XJJG-09-22)
关键词 线路板厂 含镍废水 化学沉淀法 正交试验 PCB plant nickel wastewater chemical precipitation orthogonal test
作者简介 郭琳 343009 江西吉安市井冈山大学生命科学学院E-mail guolinl121@126.com