期刊文献+

屠宰废水生化处理过程中COD快速测定法的应用及COD_(快)与BOD_5相关性研究

The application of a COD rapid monitoring method in wastewater treatment of slaughterhouse and the correlation between BOD_5 and COD.
在线阅读 下载PDF
导出
摘要 本文通过对屠宰废水生化处理过程中COD快速测定法和传统的重铬酸钾法所测数据的分析比较, 证明两种方法具有较好的一致性, 可相互替代。并根据BOD5 的测定结果得到COD快 与BOD5 的回归方程式, 且具有显著的相关性。从而为屠宰废水生物化学处理装置的运行管理快速的提供数据, 具有一定的实际意义。 In the process of treatmentfor slaughter-house wastewater, the experiment results are monitored by the COD rapid monitoring method and the traditional bichromant oxidation method and the experimental data are gotten respectively. It is the result that both methods are consistent and can be substituted by each other. It is cleaner that both methods have a significant correlation and the rapid COD monitoring method can be used in the slaughterhouse wastewater.
出处 《内蒙古环境保护》 1999年第4期14-17,共4页 Inner Mongolia Environmental Protection
关键词 屠宰废水 COD 快速测定法 废水处理 生化处理 Wastewater treatment of slaughterhouse COD rapid monitoring method correlation bichromate oxidation