期刊文献+

稀氨水稀释-电感耦合等离子体质谱法直接测定尿中碘 被引量:10

Determination of iodine in urine by inductively coupled plasma mass spectrometry with Dilute Ammonia Solution
原文传递
导出
摘要 目的:建立电感耦合等离子体质谱(ICP-MS)法测定尿中碘含量的方法。方法:采用稀氨水稀释尿样,用115In作在线内标,电感耦合等离子体质谱(ICP-MS)全定量法测定尿样中的碘。结果:方法检出限为0.78 ng/m l,回收率在86%-104%,相对标准偏差0.86%-3.61%,实际样品的分析结果和国标法没有显著性差别,测定GBW 09110k,GBW 09109 e标准参考物质中碘的含量,测定值均在标示值范围内。结论:方法操作简便、快速、灵敏、准确,适用于大批量尿样中碘的测定。 Objective:To establish a method for the determination of iodine in urine by ICP-MS.Methods: Urine were diluted to 1∶ 10 with 1% Ammonia Solution.Indium was used as on-line internal standard to correct matrix effects and the drift of analytical signals,and the contents were calculated by calibration curves.Results: The detection limits were 0.78 ng/ml,Recoveries were 86%~104%,RSD were 0.86%~3.61%.The results of analyzing samples were the same as using national standard method.The determination mean values for the certified GBW09110k and GBW09109e reference materials were within a permissible error range of the certified values.Conclusion: The method was simple,rapid,sensitive,accurate.Therefore,it can be used for the determination of iodine in urine.
出处 《中国卫生检验杂志》 CAS 2011年第6期1375-1377,共3页 Chinese Journal of Health Laboratory Technology
关键词 电感耦合等离子体质谱 尿样 氨水 Inductively Coupled Plasma Mass Spectrometry(ICP-MS) Urine Iodine Indium Ammonia Solution
作者简介 杨忠乔(1963-),男,工学硕士,副主任技师,主要从事痕量元素形态分析及方法研究。
  • 相关文献

参考文献6

二级参考文献27

  • 1方容,佘小林,钟展环.几种样品中溴与碘的离子色谱安培法测定[J].分析化学,1993,21(3):364-364. 被引量:9
  • 2李锦昕,邵一立,刘国均.流动注射-光度法测定地质样品中痕量碘[J].岩矿测试,1993,12(1):11-13. 被引量:13
  • 3莫曦明,梁旭霞,陈砚朦,彭寨玉,杜二青.电感耦合等离子体质谱法(ICP-MS)测定饮用水中碘元素[J].中国卫生检验杂志,2006,16(10):1179-1180. 被引量:30
  • 4阎玉芹,刘列钧,张亚平,赵文德,李卫东,华基礼.尿碘的砷铈催化分光光度测定方法[J].中国地方病学杂志,1997,16(1):37-40. 被引量:125
  • 5Vanhoe H, Allemeersch F V, Versieck J, et al. Effect of Solvent Type on the Determination of Total Iodine in Milk Powder and Human Serum by Inductively Coupled Plasma Mass Spectrometry [J]. Analyst. 1993,118 (8) :1015-1019.
  • 6Larsen E H, Ludwigsen M B. Determination of Iodine in Food-related Certified Reference Materials Using Wet Ashing and Determination by Inductively Coupled Plasma Mass Spectrometry [J]. J Anal At Spectrrom. 1997,12(6) : 435-439.
  • 7Cox R J, Pickford C J. Determination of Iodine-129 in Vegetable Samples by Inductively Coupled Plasma Mass Spectrometry[J]. J Anal At Spectrrom. 1992, 7 (4) :635-640.
  • 8Buchert S S A. Direct Determination of Copper and Iodine in Milk and Powder in Alkaline Solution by Flow Injection Inductively Coupled Plasma Mass Spectrometry[J]. Fresenius' J Anal Chem. 1996, 354 (3) : 323-326.
  • 9Banmann H. Rapid and Sensitive Determination of Iodine in Fresh Milk and Milk Powder by Inductively Coupled Plasma Mass Spectrometry [J]. Fresenius' J Anal Chem. 1990,338:809-812.
  • 10Gunther Radlinger, Klaus Q Heumann. Iodine Determination in Food Samples Using Inductively Coupled Plasma Isotope Dilution Mass Spectrometry[J]. Anal Chem.1998, 70(11): 2221-2224.