摘要
对粒子电极法在焦化废水三级处理工艺方面的应用进行实验。结果表明:在电解电压12 V、电解时间40 min、活性炭加入少量玻璃珠粒子电极条件下,粒子电极法对焦化废水二级处理出水的COD去除率可达到70%。
The application of the technique of particle electrode in the tertiary treatment process of coking wastewater was studied,and the appropriate application conditions were determined.The results showed that under the conditions of the electrolysis voltage of 12V,electrolysis time of 40 minutes,activated carbon with addition of a little beaded glass particle electrode,the removal efficiency of COD in the secondary treatment of coking wastewater could reach 70% using particle electrode.
出处
《水资源保护》
CAS
2011年第3期72-74,共3页
Water Resources Protection
关键词
粒子电极
深度处理
焦化废水
实验研究
particle electrode
advanced treatment
coking wastewater
experimental study
作者简介
张春华(1980-),女(满族),河北唐山人,工程师,主要从事水文水资源及水环境研究工作。E-mail:springlinda@163.com