摘要 目的:研制一种用于监测水下作业潜水员实时心率参数的便携式装置。方法:硬件系统设计为2个部分,包括心率检测单元和心率接收单元。心率检测单元位于潜水服之内,心率接收单元位于潜水服之外,2个单元之间采用无线通讯方式,心率接收单元与船上计算机之间采用有线的485传输方式,可进行长距离传输。结果:样机完成后经过反复测试,基本达到设计要求,成功实现陆上心率实时传输和水下模拟心率信号实时传输功能。无线传输模块水下可靠传输的最大距离可达10 m,且无线信号的传输距离和深度、压力无关。结论:硬件装置改进耐压和防水性能后,完全可以实现潜水员水下心电、心率信号的实时监测,并可扩展到其他生理信号的实时监测。 Objective To research a portable device which can monitor the real-time heart rate(HR) for underwater diver.Methods Hardware system included two parts,HR detecting unit and HR receiving unit.The detecting unit was inside the divingde,while the receiving unit was outside the divingde.Wireless communication was adopted between these two units,and line communication was adopted between receiving unit and a computer on board.Results Repeated tests showed that the basic design requirements were attained.The distance of wireless communication between the above two units achieved to 10 meters,and was independent of depth and pressure.Conclusion After improving the capability of pressure and water resistance to the hard devices,ECG and HR monitoring for underwater diver can be fully realized.
机构地区 海军医学研究所
出处 《医疗卫生装备》 CAS 2011年第5期13-16,共4页 Chinese Medical Equipment Journal
基金 海军医学研究所基金项目(06HY42)
关键词 潜水员 水下 心率 监测 diver underwater heart rate(HR) monitoring
作者简介 通讯作者:王云景,电话:021—81883243
  • 相关文献

参考文献7

  • 1Slater A. Instrumentation for telemetering the electroeardiogramfrom scuba divers[J]. IEEE Trans on BME, 1969,16(2) : 148.
  • 2Kennedy R S. A diver monitor system[R]. United States:Defence Technical Information Center, 1979.
  • 3Roger B. A four-channel ultrasonic telemetry system for obtaining physiological data from ocean divers[J]. Bio--telemetry, 1984,1 ( 1 ) : 50.
  • 4Robert Shukri Habib Istepanian,Bryan Woodward. Microcontroller- Based Underwater Acoustic ECG Telemetry System[J]. IEEE Transactions on Information Technology in Biomedicine, 1997,1 (2) : 150-154.
  • 5Hanish H M. A multi-channel telemetry system to monitor divers[R]. United States :Defence Technical Information Center, 1993.
  • 6姜峰.水下超声心率遥测技术的历史及现状[J].海军医学杂志,2000,21(3):273-276. 被引量:3
  • 7王健琪,董秀珍,王海滨,杨国胜,杨波,荆西京,邱力军.基于毫米波的呼吸、心率非接触检测实验[J].第四军医大学学报,2001,22(2):180-182. 被引量:32

二级参考文献6

  • 1Chuang H R,IEEE Trans Biomed Eng,1986年,33卷,7期,747页
  • 2唐永兴,王卫华,唐治维.水下超声遥测心率系统的研制[J]医疗器械,1986(03).
  • 3王兆琪.运动心电图干扰的分析及R波检出电路[J]医疗器械,1982(05).
  • 4L. Keselbrener MSc,A. Baharav MD,S. Akselrod PhD. Estimation of fast vagal response by time-dependent analysis of heart rate variability in normal subjects[J] 1996,Clinical Autonomic Research(6):321~327
  • 5李栩,吴晓力,刘登峰,白净.脉率监护电话报警装置的研究[J].北京生物医学工程,1998,17(1):6-8. 被引量:1
  • 6王磊,郑崇勋,叶继伦,刘峰.一种高效的QRS波实时检测方法[J].北京生物医学工程,1998,17(4):217-222. 被引量:19

共引文献32

同被引文献13

引证文献6

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部