摘要 某电厂安装的330MW机组在调试中发现危急遮断器装置的撑钩有时不能复位,经过分析找到了不能使撑钩复位的原因是撑钩处安装的平列双撑弹簧扭矩不足,通过增加该弹簧的扭矩解决了撑钩不能复位的问题。 In debugging of the 330MW unit of a power plant,it was found that the stay hook of the emergency governor can not reset sometimes.According to analysis,the reason of the defect mentioned above is that the moment of torsion of parallel-arranged double-supported springs installed in location near the stay hook is insufficient.The moment of torsion of the springs was increased by some means,and the problem of stay hook reset was solved.
出处 《华电技术》 CAS 2011年第4期49-51,77,共3页 HUADIAN TECHNOLOGY
关键词 危急遮断器 复位 平列双撑弹簧 扭矩 扭转变形角 emergency governor reset parallel-arranged double-support springs moment of torsion torsional deformation angle
作者简介 魏小宝(1980-),男,河南开封人,工程师,从事火力发电厂汽轮机、发电机、给水泵等主要转动机械安装、检修方面的研究工作(E-mail:shrimp319@163.com)。 单洪亮(1971-),男,河南焦作人,河南电力技术院技能专家,技师,从事火力发电厂汽轮机、发电机、给水泵等主要转动机械安装、检修方面的研究工作。