多频生物电阻抗法检测甘露醇脱水患者的体液分布

Fluid distribution in patients after administration of Mannitol by bio-impedance spectrum analysis
原文传递
导出
摘要 目的探索多频生物电阻抗法检测甘露醇脱水患者体液分布情况。方法选择使用20%甘露醇(1 g/kg体重)20 min输注脱水患者36例,未输注甘露醇20例,按性别分为两组,输注甘露醇组应用多频生物电阻抗法分别于输注甘露醇前即刻、输注甘露醇后30、60、90、120、150、180、210、240、270、300 min测定患者细胞外液量(ECW)和细胞内液量(ICW)。结果两组患者静脉输注甘露醇后ECW较输注前有显著下降(P〈0.05)的时间点为输注后120、150和180 min;静脉输注甘露醇后ICW较输注前有显著下降(P〈0.05)的时间点为输注后120 min和150min。结论输注甘露醇后2~3 h可明显降低患者细胞内液和细胞外液量。 Objective To measure the fluid distribution in patients after administration of Mannitol by the whole body bio impedance spectroscopy.Methods A total of 36 patients received Mannitol(1.0 g/kg)20 minutes.Intracellular water(ICW) and extracellular water(ECW) were measured by whole body multi frequency bio impedance spectroscopy.The measurements were made before the administration of Mannitol,at30,60,90,120,150,180,210,240,270,and 300minutes after the termination of the Mannitol infusion.Results The ECW of the patients in two groups were decreased significantly at 120 minutes、150 minutes and 180 minutes after administration of Mannitol;The ICW of the patients in two groups were decreased significantly at 120 minutes and 150 minutes after administration of Mannitol.Conclusions The ECW and ICW of the patients are decreased significantly from 60 minutes to 180 minutes after administration of Mannitol.
出处 《中国误诊学杂志》 CAS 2011年第10期2287-2289,共3页 Chinese Journal of Misdiagnostics
关键词 电阻抗 甘露醇 脱水 体液分布 Mannitol Electric Impedance Dehydration Body Fluid Compartments
作者简介 王剑强(1972-),男,河北保定人,主治医师,在读硕士。研究方向:神经外科。
  • 相关文献

参考文献8

二级参考文献43

  • 1左力,王梅,魏弘,冯丽丽.血液透析患者体液分布异常及透析对体液分布的影响[J].北京大学学报(医学版),2005,37(5):467-470. 被引量:16
  • 2Locatelli F, Covic A, Chazot C, et al. Hypertension and cardiovascular risk assessment in dialysis patients[J]. Nephrol Dial Transplant, 2004, 19(5): 1058-1068.
  • 3Katzarski KS, Charra B, Luik AJ, et al. Fluid state and blood pressure control in patients treated with long and short hemodialysis[J]. Nephrol Dial Transplant,1999,14(2):369-375.
  • 4Spiegel DM,Bashir K,Fich B. Bioimpendance resistance ratio for the evaluation of dry weight in hemodialysis[J]. Clin Nephrol, 2000,53(2) : 108-114.
  • 5Maria A, Alejandro M, Mario E, et al. Blood pressure and body water distribution in chronic renal failure patients[J]. Nephrol Dial Transplant, 2001,16 ( suppl 1 ) : 94- 97.
  • 6Dionisio P, Valenti M, Bergia R, et al. Influence of the hydration state on blood pressure values in a group of patients on the regular maintenance hemodialysis[J]. Blood Purif, 1997,15:25-33.
  • 7Krassimir S, Katzarski, Jose C, et al. Extracellular volume changes and blood pressure levels in hemodialysis patients[J]. Hemodial Int, 2003,7(2) : 135-142.
  • 8Shuta I, Aldo JP. Methods of assessment of volume status and intercompartmental fluid shifts in hemodialysis patients: implications in clinical practice[J]. Seminars in Dialysis, 2004, 17 ( 1 ) : 37-43.
  • 9Foley RN, Herzog CA, Collins AJ. Blood pressure and longterm morality in United States hemodialysis patients: USRDS Waves 3 and 4 study. Kidney Int, 2002, 62:1784-1790.?A
  • 10Locatelli F, del Vecchio L, Manzoni C. Morbidity and mortality on maintenance hemodialysis. Nephron, 1998, 80:380-400.

共引文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部