期刊文献+

壁挂式太阳能空气集热器变风量控制运行效果研究 被引量:5

Experimental Study on Operational Effect of Wall-mounted Solar Air Collector (WSAC) by VAV Control
原文传递
导出
摘要 本文以壁挂式太阳能空气集热器(Wall-mounted Solar Air Collector,WSAC)为研究对象,采用现场实测和理论分析的方法,通过研究太阳辐射照度、送风量与WSAC瞬时效率以及纯效率的关联性,提出了综合考虑建筑能耗时变风量工况下提高WSAC运行效率的途径。而后,利用实体大实验房,分别采用连续定风量送风、变风量送风以及间歇定风量送风的运行方式,对WSAC热性能及节能效果进行了实验研究。结果表明,在考虑WSAC纯效率的情况下,变风量送风的运行效率优于其它送风方式,相对连续定风量送风节能63%,同时还得到了随着太阳辐射照度变化的最佳控制运行模式。 In this paper,taking the wall-mounted solar air collector(WSAC) as a research object,the experimental and theoretical studies were carried out.In detail,based on the relationships of solar irradiance,supply air flowrate,WSAC transient thermal efficiency and WSAC net efficiency,a strategy to improve the operational efficiency was proposed under the VAV conditions when the building energy consumption was considered.Furthermore,in a physical experimental room,WSAC thermal performance and energy-saving effect were analyzed under the air supply modes of constant,variable and intermittent air volumes,respectively.The results shown that the net efficiency of VAV air supply mode was larger than others in considering of the WSAC net efficiency,and compared to the constant air volume air supply mode,the energy-saving rate was 63%.In addition,the best control operation mode was obtained with the changing of solar irradiance.
出处 《建筑科学》 北大核心 2011年第4期31-35,共5页 Building Science
基金 国家自然科学基金项目(50778032) "十一五"国家科技支撑重点项目(2006BAA04B04)
关键词 壁挂式太阳能空气集热器 变风量 瞬时热效率 节能 wall-mounted solar air collector(WSAC) VAV transient thermal efficiency energy-saving
作者简介 [作者简介]张志成(1986-),男,在读硕士研究生[联系方式]zczhang.hvac@gmail.com
  • 相关文献

参考文献9

二级参考文献27

  • 1陈滨,庄智,杨文秀.被动式太阳能集热墙和新型节能灶炕耦合运行模式下农村住宅室内热环境的研究[J].暖通空调,2006,36(2):20-24. 被引量:20
  • 2Chen Z D, Bandopadhayay P, Halldorsson J, et al. An experimental investigation of a solar chimney model with uniform wall heat flux [J]. Building and Environment, 2003, 38 (7): 893-906.
  • 3Tiwari A, Sodha M S. Parametric study of various configurations of hybrid PV/thermal air collector: experimental validation of theoretical model [J]. Solar Energy Materials & Solar Cells, 2007, 91 (1) : 17-28.
  • 4Lin Wenxian, Gao Wenfeng, Liu Tao. A parametric study on the thermal performance of cross-corrugated solar air collectors [ J ]. Applied Thermal Engineering, 2006,26 (10) : 1043-1053.
  • 5Zhai X Q, Dai Y J, Wang R Z. Experimental investigation on air heating and natural ventilation of a solar air collector [J]. Energy and Buildings, 2005, 37 (4): 373-381.
  • 6Romdhane B S. The air solar collectors: comparative study, introduction of baffles to favor the heat transfer [J]. Solar Energy, 2007, 81 (1): 139-149.
  • 7Karim M A, Hawlader M N A. Performance evaluation of a v-groove solar air collector for drying applications [ J ]. Applied Thermal Engineering, 2006, 26 (1): 121-130.
  • 8Ucar A, Inalh M. Thermal and exergy analysis of solar air collectors with passive augmentation techniques [J]. International Communications in Heat and Mass Transfer, 2006, 33 (10) : 1281-1290.
  • 9Koyuncu T. Performance of various design of solar air heaters for crop drying applications [ J ]. Renewable Energy, 2006, 31 (7): 1073-1088.
  • 10Duffle J A, Beckman W A. Solar energy thermal processes[M]. New York : Wiley, 1974.

共引文献44

同被引文献22

引证文献5

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部