期刊文献+

气水比对高速给水曝气生物滤池脱氮效果的影响 被引量:9

EFFECT OF AIR/WATER RATIO ON HIGH-RATE UBAF FOR THE REMOVAL OF AMMONIA
在线阅读 下载PDF
导出
摘要 以珠江水源水为高速给水曝气生物滤池(high-rate UBAF)预处理中试试验对象,研究采用单孔膜曝气滤头曝气系统时,滤池于不同气水比工况下对珠江水源水的脱氮效果。结果表明:水温为30℃,水力停留时间为15 min,处理水量为64 m3.h-1,滤速为16 m.h-1时,随着气水体积比从0.1增加至0.7,DO浓度呈对数上升;当气水体积比大于0.5时,预处理出水NH4+-N质量浓度基本上小于0.5 mg·L-1,NO2--N小于0.110 mg·L-1。 The pilot test took the raw water from Pearl River as the object that pre-treated by high-rate UBAF. When using single-pore membrane aerating filter head as the filter's aeration system, study on the nitrogen removal by high-rate UBAF was carried out under various air/water ratio conditions. Results show that in the temperature of 30 ℃, and under the retention time of 15 min, with 64 m3·h^-1 of water flow, and 16 m ·h^-1 of filtration rate, when the air/water ratio is stepped-up from 0.1 to 0.7, the DO concentration increases logarithmically. When the air/water ratio is above 0.5, the value of the effluent ammonia is lower than 0.5 mg·L^-1, while the nitrite is lower than 0.110 mg·L^-1.
出处 《水处理技术》 CAS CSCD 北大核心 2011年第3期88-90,95,共4页 Technology of Water Treatment
基金 国家十一五水专项课题(2008ZX07423-002-1)
关键词 高速给水曝气生物滤池 气水比 氨氮 微污染原水 high-rate UBAF air/water ratio ammonia nitrogen micro-polluted raw water
作者简介 邵志昌(1986-),男,硕士研究生,从事给水技术与水污染控制技术研究;联系电话:15915725397;E-maihshaozhichang@qq.com
  • 相关文献

参考文献8

二级参考文献43

共引文献149

同被引文献80

引证文献9

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部