期刊文献+

DE—CTA和DS—CTA在头颈部CTA的比较 被引量:2

Comparison of Cranial and Cervical CTA Between DE-CTA and DS-CTA
在线阅读 下载PDF
导出
摘要 [目的]探讨头颈血管双能量血管造影(DE-CTA)的辐射安全性及临床应用价值.[方法]应用CT减影血管成像(DS-CTA)对60例疑头颈部血管病变者进行扫描,并同时进行DE-CTA的模拟扫描,比较两者的辐射剂量;另选取一组60例疑头颈部血管病变者行DE-CTA扫描,在DS-CTA、DE-CTA两组扫描图像中分别选择四个解剖部位,对比测定其血管内造影剂浓度并统计两组扫描的时间.[结果]头颈血管DE-CTA辐射剂量高于DS-CTA约17.12%,近段血管图像质量等同于DS-CTA,远段血管图像质量逊于DS-CTA,完成扫描时间明显短于DS-CTA.[结论]头颈部血管DE-CTA与DS-CTA扫描各有其长处及缺点,应根据患者的综合情况选择合理的扫描方案,获得最佳图像. [Objective] To explore the radioactive safety and clinical value of dual energy CT angiography (DE-CTA) of cranial and cervical vessel. [Methods] Sixty patients suspected of cranial and cervix vascular diseases underwent digital subtraction angiography(DS-CTA). Meanwhile, DE-CTA simulating-scan was performed. The radiation doses were compared between DA-CTA and DE-CTA. Another 60 patients suspected of cranial and cervix vascular diseases underwent DE-CTA. Four different anatomic slices were chosen to detect the concentration of intravascular contrast medium and calculate scanning time in all cases. [Results] The radi- ation dose of DECTA was 17.12% which was higher than that of DS-CTA. Image quality was equal in two groups in the proximal segment of vessels, but was different in the distal segment of vessels. Scanning time decreased significantly in DE-CTA group. [Conclusion] Compared with DS-CTA, DE-CTA has both advantages and disadvantages. Radiologists should choose reasonable scanning method according to the complex condition of the patients so as to obtain the best image.
机构地区 解放军
出处 《医学临床研究》 CAS 2010年第10期1840-1842,共3页 Journal of Clinical Research
关键词 头部/放射摄影术 颈/放射摄影术 体层摄影术 X线计算机 血管造影术 head/RA neck/RA tomography,X-ray computed angiography
  • 相关文献

参考文献7

二级参考文献21

  • 1张杨,李彩霞.三维数字血管造影在颅内动脉瘤诊治中的应用[J].中国介入影像与治疗学,2007,4(1):35-38. 被引量:5
  • 2吕发金,谢鹏,罗天友,张志伟,何怡红,孙晓川,牟君,方维东.数字减影CT血管成像在蛛网膜下腔出血诊断中的价值[J].中国医学影像技术,2007,23(1):45-48. 被引量:115
  • 3Nakayama Y,Awai K,Funama Y,et al.Abdominal CT with low tube voltage:preliminary observations about radiation dose,contrast enhancement,image qulity,and noise.Radiology,2005,237(3):945-951.
  • 4Johnson TR,Krauss B,Sedlmair M,et al.Material differentiation by dual energy CT:initial experience.Eur Radiol,2007,17(6):1510-1517.
  • 5Graser A,Johnson TR,Bader M,et al.Dual energy CT characterization of urinary calculi:initial in vitro and clinical experience.Invest Radiol,2008,43(2):112-119.
  • 6Jayaraman MV,Mayo-Smith WW,Tung GA,et al.Detection of intracranial aneurysms:multi-detector row CT angiography compared with DSA.Radiology,2004,230(2):510-518.
  • 7Fishman EK,Ney DR,Heath DG,et al.Volume rendering versus Maximum intensity projection in CT angiography:what works best,when,and why.Radiographic,2006,26(3):905-922.
  • 8Tomandl BF,Kostner NC,Schempershofe M,et al.CT angiography of intracranial aneurysms:a focus on postprocessing.Radiographic,2004,24(3):637-655.
  • 9Matsumoto M,Kasuya H,Sato T,et al.Can 3D-CT angiography (3D-CTA) replace conventional catheter angiography in ruptured aneurysm surgery? Our experience with 162 cases.Fukushima J Med Sci,2007,53(2):85-94.
  • 10Schoepf UJ, Costello P. Multidetector-row CT imaging of pulmonary embolism. Semin Roentgenol, 2003,38(2) : 106-114.

共引文献77

同被引文献12

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部