期刊文献+

64层螺旋CT检测冠状动脉狭窄的研究 被引量:2

Contrast Study of 64-slice Spiral CT Detection of Coronary Artery Stenosis in the Elderly and the Young
在线阅读 下载PDF
导出
摘要 目的探讨64层螺旋CT在诊断老年及中青年冠状动脉狭窄的敏感性等指标的差异。方法对203例经冠状动脉造影证实为冠脉狭窄患者的临床病例资料进行分析。结果老年患者轻、中、重度冠脉狭窄的敏感性分别为78.3%、79.2%、90.6%;中青年患者之敏感性分别为91.8%、86.7%、91.7%。结论 64层螺旋CT诊断老年冠脉狭窄的敏感性低于中青年,轻、中度狭窄时差异有统计学意义,重度狭窄时敏感性无统计学差异。 Objective To discuss the index diference of sensitivity of 64-slice spiral CT in diagnosing coronary artery stenosis in the elderly and the young. Methods An analysis was made to the clinical data of 203 cases with coronary artery stenosis conformed by coronary angiography. Results The sensitivities of the elderly with mild,moderate and severe coronary artery stenosis were 78. 3% ,79. 2% and 90. 6% respectively while those of the young were 91. 8% ,86. 7% and 91. 7% respectively. Conclusion The sensitivity of 64-slice spiral CT in diagnosing coronary artery stenosis of the elderly is lower than that of the young,the diference is of statistical sign ificance in diagnosing the mild and moderate stenosis but of no statistical significance in diagnosing the severe stenosis.
作者 陈耀强
出处 《中国实用医药》 2010年第24期7-8,共2页 China Practical Medicine
关键词 64层螺旋CT 老年 中青年 冠状动脉狭窄 64-slice spiral CT the elderly The young coronary artery stenosis
  • 相关文献

参考文献9

  • 1Nieman K,Cademartiri F,Lemos RA,et al.Raliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.Circulation,2002,106(16):2051-2054.
  • 2黄美萍,刘其顺,刘辉,梁长虹,张绍斌.多层螺旋CT冠状动脉成像质量及对冠状动脉病变诊断准确性的评价[J].中华放射学杂志,2006,40(9):984-987. 被引量:83
  • 3Rensing BJ,Bongae-s AHH,Van Geuns RJM,et al.Intravenous coronary angiography using electron beam computed tomography.ProgCardiovase Dis,1999,42:1139-1148.
  • 4Nieman K,Vander Lugt A,Pattynaman PM,et al.Noninvasive visualization of atheroselemtie plaque with election beam and multisliee spiral computed tomography.J Interv Cardiol,2003,16:123-128.
  • 5Takahashi N,Bae KT.QuantifSCAtion of coronary artery calaium with multi detector row CT:assessing interscan variability wi th diferent tube currents pilot study.Radiology,2003,228:101-106.
  • 6Staford W,Thompson BH,Bums TL,et al.Coronary artery calcium quantitcation at multi detector lOW heliealCT veYsus electron beam CT.Radiology,2004,230:397-402.
  • 7伊婕,李绍科,安毅.64层螺旋CT冠状动脉成像在冠脉狭窄诊断中的临床应用[J].心脑血管病防治,2007,7(5):316-318. 被引量:9
  • 8王照谦.多层螺旋cT冠脉成像的现状和临床举例.心脏病学实践.人民卫生出版社,2005:647-654.
  • 9Beeker CR,Ohnesorge BM,Sehoepf UJ,et al.Current development of cardiac imaging with multidetector row CT.Europen Radiology,2000,36(2):97-103.

二级参考文献14

共引文献88

同被引文献110

引证文献2

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部