摘要 带三相四线制二极管整流桥负载的发电机始终处于非对称运行状态。为了进行系统性能的解析分析,将发电机的d、q轴变量分解为低频和高频分量分别处理,忽略了转子回路对高频电流的电阻及阻尼绕组对低频分量的作用,假定交、直轴超瞬态电抗相等,建立了同步发电机的等效电路模型,并给出了稳态时等效发电机的Park方程、相量图及稳态量的计算方法。分别通过发电机整流桥硬件系统的试验及在EMTDC软件环境下详细模型的仿真对等效电路模型进行了验证,结果证明了其正确性。所给出的等效电路模型可应用于此类系统的性能分析与小扰动稳定性研究。 A synchronous generator with a 3-phase-and-4-wire diode-bridge rectifier load operates in an asymmetric mode all the time.In order to investigate the performance,the d- and q-axis variables of 3-phase generator were decomposed into low- and high-frequency components and treated respectively,neglecting the effect of high-frequency currents on the rotor resistances and that of the damper windings on low-frequency components.With the d-axis sub-transient reactance equal to the q-axis one,the equivalent circuit model of synchronous generator was established.The Park′s equations,phasor diagram and calculation method of steady variables of equivalent generator were also presented.The equivalent circuit model was validated by the experiment on a hardware system and simulation of the detailed model in EMTDC environment.The results prove that the equivalent circuit model can be used for the performance analysis and the small-signal disturbance stability assessment in such systems.
出处 《海军工程大学学报》 CAS 北大核心 2010年第3期11-15,共5页 Journal of Naval University of Engineering
基金 国家自然科学基金资助项目(50607020 50721063)
关键词 同步发电机 三相四线制 二极管整流桥 等效电路模型 synchronous generator 3-phase-and-4-wire system diode-bridge rectifier equivalent circuit model
作者简介 魏克银(1978-),男,博士生,主要研究方向为集成化发电系统的设计与性能分析,Email:ky_wei@126.com。
  • 相关文献

参考文献7

  • 1RENDUSARA D A,CENGELCI E,ENJETI P N,et al.Analysis of common mode voltage-"neutral shift" in medium voltage PWM adjustable speed drive (MV-ASD) systems[J].IEEE Trans.Power Electron.,2000,15(6):1124-1133.
  • 2BUSHMAN R E.Calculation of neutral voltage shift in LCI driven induction motors[J].IEEE Trans.Energy Conv.,1991,6(3):507-513.
  • 3LIAN K L,PERKINS B K,LEHN P W.Harmonic analysis of a three-phase diode bridge rectifier based on sampled-data model[J].IEEE Trans.Power Delivery,2008,23(2):1088-1096.
  • 4YANG Qing,MA Wei-ming,SUN Jun-zhong.Stability analysis of a synchronous generator with simultaneous AC and rectified DC load[C]// Proc.5th Int.Conf.Elect.Machines and Systems.Shenyang,China:ICEMS,2001.
  • 5马伟明,胡安,刘德志,张盖凡.同步发电机-整流器-反电动势负载系统的稳定性分析[J].电工技术学报,2000,15(1):1-6. 被引量:24
  • 6SUDHOFF S D,CORZINE K A,HEGNER H J,et al.Transient and dynamic average-value modeling of synchronous machine fed load-commutated converters[J].IEEE Trans.on Energy Conv.,1996,11(3):508-514.
  • 7WU Xu-sheng,MA Wei-ming,SUN Jun-zhong,et al.Parameter measurement of multi-phase synchronous machines with AC and DC output[C]// Proc.5th Int.Conf.Elect.Machines and Systems.Shenyang,China:ICEMS,2001.

二级参考文献3

  • 1马伟明,海军工程学院学报,1995年,3期
  • 2马伟明,海军工程学院学报,1995年,4期
  • 3马伟明,博士学位论文,1995年

共引文献23

同被引文献5

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部