期刊文献+

潘口水电站厂房结构动力分析 被引量:1

Dynamic Analysis on Pankou Hydropower Plant Structural
在线阅读 下载PDF
导出
摘要 由于水电站厂房结构比较复杂,网格划分非常困难,本文在建立厂房有限元模型中采用了过渡单元来进行网格划分。为说明采用过渡单元的合理性,文中用梁模型验证了其计算精度。在此基础上,对厂房结构进行了模态分析和厂房自振频率校核,得出可以计算厂房整体结构而无需单独计算蜗壳和尾水管就可以满足计算要求的结论。最后,计算和分析了厂房结构的校核工况、地震工况及尾水管的检修工况,并进行了应力强度校核。 Meshing is very hard because of the structure of the hydropower plant is complex.So,this article have taken use of transitional elements for meshing in establishing FEM model of the plant.For explaining the rationality of using transitional element,there used beam model to verify its accuracy in article.Based on it,this article have taken modal analysis and checked nature frequency of plant structure,then have reached the conclusion of there is no need to caculate the partial structure just only through caculating whole of the structure we can get the results.At last,there have caculated and analysised checking condition,seismic condition,maintenance condition of tube and have checked stress intensity.
作者 胡海鑫
出处 《吉林水利》 2010年第6期13-17,共5页 Jilin Water Resources
关键词 水电站厂房 过渡单元 模态 动力 Powerhouse Transitive element Model Dynamic
作者简介 胡海鑫(1983-),男。湖北武穴人,硕士研究生,研究方向为地下洞室结构稳定性分析。
  • 相关文献

参考文献5

  • 1ANSYS建模及分网指南.ANSYS中国,2000.
  • 2DL5073-2000.水工建筑物抗震设计规范[S].[S].,..
  • 3SL266-2001.水电站厂房设计规范[S].[S].,..
  • 4练继建,王海军,王日宣.河床式水电站厂房结构动力特性研究[J].水利水电技术,2004,35(8):37-40. 被引量:14
  • 5SL/T191-96.水工混凝土结构设计规范[S].[S].,..

二级参考文献4

  • 1Peter Koknke.ANSYS,Inc[J].Theory Release,1994,(5),(7).
  • 2舒扬棨 王日宣.水电站厂房动力分析[M].北京:水利水电出版社,1987..
  • 3王日宣.并联体系结构自振特性与地震荷载研究[A]..水电站与水工建筑物振动和抗振理论论文集[C].天津:天津大学出版社,1991..
  • 4郭永刚,张祁汉.三峡水电站厂房结构自振特性研究[J].水力发电,2002,28(1):13-15. 被引量:11