期刊文献+

旋转线圈测量法测量BEPCⅡ对撞区超导磁铁磁场 被引量:1

Magnetic Field Measurement of BEPCⅡ Superconducting Magnets by Using Rotating Coil
在线阅读 下载PDF
导出
摘要 北京正负电子对撞机二期工程(BEPCⅡ)中的超导磁铁用来提高BEPCⅡ的对撞亮度,并对闭轨和耦合进行校正。超导磁铁要尽可能靠近对撞点(IP),并浸泡在1.0T的探测器BESⅢ螺线管磁场中。对撞点两侧各有1块超导磁铁,每块都包含有聚焦磁铁SCQ、水平偏转磁铁SCB/HDC、垂直校正子VDC、斜四极子SKQ及反螺线管AS等功能磁铁。利用旋转线圈的测量方法对SCQ、SCB/HDC、VDC、SKQ等进行测量,了解其积分场、高次谐波及沿束流运行方向的局部磁场。通过与BNL在垂直杜瓦中的测量结果进行的比较可知,高次谐波测量结果差别不大;与张力线的比较可知,SCQ及SCB的主极矩偏差小于3×10-3。表明提出的计算方法可进行磁场的绝对测量。 Superconducting interaction region (IR) magnets for Beijing Electron Positron Collider Upgrade Project (BEPCⅡ) are used for increasing the BEPCⅡ luminosity,correcting close orbit and coupling.These magnets are placed as close as possible to the interaction point (IP),immersed within the BESⅢ detector solenoid field of 1.0 T.These magnets are designed into two magnet packages at each side of the IP with each contained inside a magnet cryostat.Each superconducting magnet package includes several function magnets of SCQ,SCB/HDC,VDC,SKQ and AS.Some of them,such as SCQ,SCB/HDC,VDC,SKQ were measured by rotating coil,and the integrals field and high order harmonic contents,local field along the beam line are known in details.Comparing these results with that from BNL which were measured inside the vertical Dewar,it’s found that there were only small differences.Comparing with the results from the stretched wire,for SCQ and SCB as examples,it’s found that the differences for the main fields are less than 3×10-3.As a result,the method presented in the paper can be used for absolute magnetic field measurements.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2010年第5期617-622,共6页 Atomic Energy Science and Technology
基金 BEPCⅡ国家重大工程改进项目资助
关键词 超导磁铁 旋转线圈 主线圈 反抵线圈 superconducting magnet rotating coil main coil bucking coil
作者简介 彭全岭(1967-),男,河南鄢陵人,副研究员,博士,加速器磁铁专业
  • 相关文献

参考文献5

  • 1PARKER B.Brookhaven National Laboratory magnet division note AM-No-328,design report for the BEPCⅡ superconducting IR magnets[R].USA:Brookhaven National Laboratory,2003.
  • 2PENG Q L,PARKER B,MARONE A.BEPCⅡ iteraction region superconducting magnet system[J].IEEE Transactions on Applied Superconductivity,2004,14(2):539-541.
  • 3JAIN A.Measurements of field quality using harmonic coils[R].Houston,USA:US Particle Acclerator School on Superconducting Accelerator Magnets,2001.
  • 4TANABE J.Iron dominated electromagnets design,fabrication,assembly and measurement,SLAC-R-754[R].USA:[s.n.] ,2005.
  • 5PDI5025 precision digital integrator reference manual[M].Version 2.2.Switzerland:METROLAB Instruments SA,1993.