龙滩水电站设置尾水阻抗式调压井。对调压井阻抗板在水荷载及自重作用下的最大应力部位、应力及变位量级、板体结构、配筋问题等做了探索,认为采用全固定支座厚2.0m的肋形整体板较为适宜。
The tailrace impedance surge chamber is going to be used on Longtan hydropower station. Some questions about the impedance board of surge chamber will be discussed in the paper, such as maximum stress position, stress, displacement, board structure and reinforcement, which will be acted under the water load and gravity. The result is that the 2 meter thick ribbed whole board, whose bearing will be fixed, is available.