摘要
从电焊机保护接地(或接零)的规则、电源线与焊钳的安全技术、控制电器的安全技术、电焊工作业中的安全保障措施等四个方面,探讨了电弧焊作业中如何防范触电事故的技术措施,实践证明,所述的安全要求和技术方法对于电弧焊作业的安全管理和安全生产具有很高的实用价值。
The technical measures for preventing electric shock accidents in arc welding operation are discussed in terms of the rules on the protective earthing( or zero connection ) of electric welding machines, security technology of power lines and welding clamps, security technology of control electric appliances and safety measures taken in welding operation. The practice shows that the safety requirements and technical methods stated here are of highly practical value for the safety management and safe production work in arc welding operation.
出处
《林业劳动安全》
2010年第2期28-31,共4页
Forestry Labour Safety
关键词
电孤焊
电焊机
安全
触电
绝缘
arc welding
electric welding machine
safety
electric shock
insulation
作者简介
王水成(1955-),男,教授级电气工程师,藏书家,现供职于中国平煤神马能源化工集团天宏焦化公司,主要从事仪器仪表、自动控制和电气安全技术工作,获得已授权和已通过审查的国家专利27项,获省、市(厅、局)级科技成果及优秀学术论文奖50多次,出版专业著作1部。