摘要
针对成都理工大学核地球物理与地球化学研究室研制的在线瞬发γ中子活化分析(PGNAA)装置,利用MCNP程序对水泥样品进行模拟计算分析,得到瞬发γ射线产额随样品厚度和样品形态(块状、颗粒、粉末等)的变化关系。根据模拟结果,确定样品厚度以17 cm为宜,并应在在实际分析前将水泥生料粗加工成细颗粒状。
Based on the prompt gamma neutron activation analysis(PGNAA) system device developed by the nuclear geophysical and geochemical research room,Chengdu University of Technology,MCNP process was adopted to simulate and calculate cement sample parameters.Results of calculations showed that the relationship between prompt γ yield and the sample's thickness and shape(massive,granules,powders,etc.) was obtained.According to the simulation,the optimal sample thickness is determined to be 17 cm and the cement raw materials should be processed into fine particles before application in the actual analysis of PGNAA.
出处
《金属矿山》
CAS
北大核心
2010年第4期134-136,145,共4页
Metal Mine
基金
国家创新方法工作专项(编号:2008IM021500)
四川省科技条件平台项目(编号:2008GZ0040
2008GZ0197)
关键词
蒙特卡罗法
MCNP
瞬发γ中子活化分析
水泥样品参数
Monte-Carlo method
MCNP
Prompt gamma neutron activation analysis
Cement sample parameters
作者简介
杨剑波(1973-),男,成都理工大学核技术与自动化工程学院,博士研究生,610059四川省成都市成华区二仙桥东三路1号成都理工大学先达信箱。