摘要
从理论上分析了FGD废水与灰水的作用机理,研究了FGD废水对循环冲灰系统中的重金属排放和碳钢腐蚀的影响。结果表明:重金属排放浓度取决于灰水pH值,絮凝吸附作用有利于进一步降低重金属残留量。
The reaction mechanism of the FGD wastewater and ash - sluicing water were analyzed theoretically. The simulation experiment of the impacts of FGD wastewater on the heavy metal emission and carbon steel cor- rosion in circulation ash - sluicing water system were studied. The results indicated that the heavy metal emis- sions density was decided by the pH value of ash - sluicing water and the flocculation adsorption was advantageous to further reduction of the heavy metal residual quantity.
出处
《电力科技与环保》
2010年第2期56-58,共3页
Electric Power Technology and Environmental Protection
关键词
FGD
废水
灰水
影响
flue gas desulfurization
astewater
sh - sluicing water
impact
作者简介
方伟明(1964-),男,广东开平人,高级工程师,从事火电厂化学管理工作。E—mail:bqzhou@whu.edu.cn