期刊文献+

Performance and Flow Condition of Small-Sized Axial Fan and Adoption of Contra-Rotating Rotors 被引量:9

Performance and Flow Condition of Small-Sized Axial Fan and Adoption of Contra-Rotating Rotors
原文传递
导出
摘要 Small-sized axial fans are used as air coolers for electric equipments.But there is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices.Therefore,higher rotational speed design is conducted,although it causes the deterioration of the efficiency and the increase of noise.Then the adoption of contra-rotating rotors for the small-sized axial fan is proposed for the improvement of the performance.In the present paper,the performance and the internal flow condition of the small-sized axial fan are shown as a first step of the research for the contra-rotating small-sized axial fan and the important points to apply contra-rotating rotors to the small-sized axial fan are discussed.Furthermore,the numerical flow analysis is conducted to investigate the performance of the contra-rotating small-sized axial fan and internal flow conditions and pressure distributions are clarified and the effect of contra-rotating rotors is considered.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2010年第1期1-6,共6页 热科学学报(英文版)
基金 supports by the project research aid from The University of Tokushima,Japan Science and Technology Agency and Komiya research aid
关键词 Small-sized axial fan Contra-rotating rotors Numerical analysis PERFORMANCE Internal flow 轴流风机 旋转 转子 性能 小尺寸 轴流式风机 流量 内部流动
  • 相关文献

参考文献1

二级参考文献1

共引文献19

同被引文献28

  • 1毛军,杨立国,郗艳红.大型轴流风机叶片的气动弹性数值分析研究[J].机械工程学报,2009,45(11):133-139. 被引量:34
  • 2DongliangQUAN SonglingLIU JianghaiLI GaowenLIU.Cooling Performance of an Impingement Cooling Device Combined with Pins[J].Journal of Thermal Science,2005,14(1):56-61. 被引量:4
  • 3Akinori Furukawa,Toru Shigemitsu,Satoshi Watanabe.Performance Test and Flow Measurement of Contra-Rotating Axial Flow Pump[J].Journal of Thermal Science,2007,16(1):7-13. 被引量:20
  • 4Yang LI,Hua OUYANG,Zhao-hui DU.Experimental research on aerodynamic performance and exit flow field of low pressure axial flow fan with circumferential skewed blades * * Project supported by the National Natural Science Foundation of China (Grant No.50406017).[J]. Journal of Hydrodynamics, Ser.B . 2007 (5)
  • 5János Vad,Ferenc Bencze.Three-dimensional flow in axial flow fans of non-free vortex design[J]. International Journal of Heat and Fluid Flow . 1998 (6)
  • 6Y. H. Shin,K. H. Kim,C. S. Kang.Unsteady pressure measurements aroundrotor of an axial flow fan under stable and unstable operatingconditions. JSME International Journal . 2005
  • 7Zhou Jian-hui,Yang Chun-xin.Parametric Design and Numerical Simulation of the Axial-Flow Fan for Electronic Devices. Components and Packaging Technologies, IEEE Transactions on . 2010
  • 8Lee, Ki-Sang,Kim, Kwang-Yong,Samad, Abdus.Design optimization of low-speed axial flow fan blade with three-dimensional RANS analysis. Journal of Mechanical Science and Technology . 2008
  • 9Yan Xiao-kang,Wang Ii-jun,Zhangjing-song et al.Numericaland experimental investigationoneffect of installation angleof rotor blade on axialflow fan. IEEE International Conference onMechanicaland Electrical Technology . 2010
  • 10Cho L,Choi H,Lee S,et al.Numerical and experimental analyses for the aerodynamic design of high performance counter-rotating axial flow fans. . 2009